H3C-FCOE-MODE-MIB :: h3cFcoeModeCfgLastResult

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › H3C-FCOE-MODE-MIB › h3cFcoeModeCfgLastResult

h3cFcoeModeCfgLastResult

Module: H3C-FCOE-MODE-MIB

OID (symbolic): H3C-FCOE-MODE-MIB::h3cFcoeModeCfgLastResult

OID (numeric): 1.3.6.1.4.1.2011.10.2.135.1.2

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: This object specifies the result of the latest FCoE mode configuration.

The object has four values: success - Configured successfully. noLicence - Configured unsuccessfully for lack of licence. needReset - Configured unsuccessfully, because the desired mode is not non-FCoE mode, and the mode should be first set to non-FCoE mode. unknownFault - Configured unsuccessfully for unknown fault.

What is h3cFcoeModeCfgLastResult?

This read-only value reports the outcome of the most recent attempt to change the switch's FCoE operating mode via h3cFcoeModeCfgMode, returning one of success, noLicence (the required feature license is missing), needReset (the switch must first be set to non-FCoE mode before this mode change is possible), or unknownFault. An administrator checks this immediately after attempting an FCoE mode change to confirm it actually took effect, and to get a specific reason if it didn't, rather than having to guess why the mode didn't switch. For example, seeing a value of needReset after trying to jump directly from FCF mode to Transit mode confirms the switch needs to be returned to non-FCoE mode first, matching the conversion rule described for h3cFcoeModeCfgMode.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2011.10.2.135.1.2
snmpwalk -v2c -c public <target> H3C-FCOE-MODE-MIB::h3cFcoeModeCfgLastResult

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2011.10.2.135.1.2.1
snmpget -v2c -c public <target> H3C-FCOE-MODE-MIB::h3cFcoeModeCfgLastResult.1

Start monitoring H3C data-center switch with FCoE support (FCF/ENode mode) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the H3C-FCOE-MODE-MIB::h3cFcoeModeCfgLastResult OID value, configure state conditions and alerts, and monitor any H3C data-center switch with FCoE support (FCF/ENode mode) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2011huaweiEXPERTV2-MIB
1.3.6.1.4.1.2011.10h3cHUAWEI-3COM-OID-MIB
1.3.6.1.4.1.2011.10.2h3cCommonHUAWEI-3COM-OID-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2011.10.2.135h3cFcoeModeH3C-FCOE-MODE-MIB
1.3.6.1.4.1.2011.10.2.135.1h3cFcoeModeMibObjectsH3C-FCOE-MODE-MIB
1.3.6.1.4.1.2011.10.2.135.1.2h3cFcoeModeCfgLastResultH3C-FCOE-MODE-MIB