H3C-FC-FLOGIN-MIB :: h3cFcFLoginSuppClassRequested

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › H3C-FC-FLOGIN-MIB › h3cFcFLoginSuppClassRequested

h3cFcFLoginSuppClassRequested

Module: H3C-FC-FLOGIN-MIB

OID (symbolic): H3C-FC-FLOGIN-MIB::h3cFcFLoginSuppClassRequested

OID (numeric): 1.3.6.1.4.1.2011.10.2.127.3.1.1.1.9

Node type: OBJECT-TYPE

Type: H3cFcClassOfServices

Access: read-only

Description: The object indicating the supported Classes that the logged-in Nx_Port has requested.

What is h3cFcFLoginSuppClassRequested?

A read-only value reporting which Fibre Channel classes of service, such as Class 2 or Class 3, the logged-in Nx_Port requested support for during login. This tells an admin which delivery guarantees, acknowledged Class 2 versus unacknowledged Class 3, the connected device is capable of and asked to use, useful for confirming a device supports the class of service the SAN design expects. A device requesting only Class 3 tells the admin it relies on higher-layer protocols for delivery confirmation rather than fabric-acknowledged Class 2 service.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2011.10.2.127.3.1.1.1.9
snmpwalk -v2c -c public <target> H3C-FC-FLOGIN-MIB::h3cFcFLoginSuppClassRequested

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2011.10.2.127.3.1.1.1.9.1
snmpget -v2c -c public <target> H3C-FC-FLOGIN-MIB::h3cFcFLoginSuppClassRequested.1

Start monitoring H3C Fibre Channel switch (fabric login info) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the H3C-FC-FLOGIN-MIB::h3cFcFLoginSuppClassRequested OID value, configure state conditions and alerts, and monitor any H3C Fibre Channel switch (fabric login info) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2011huaweiEXPERTV2-MIB
1.3.6.1.4.1.2011.10h3cHUAWEI-3COM-OID-MIB
1.3.6.1.4.1.2011.10.2h3cCommonHUAWEI-3COM-OID-MIB
1.3.6.1.4.1.2011.10.2.127h3cSanH3C-VSAN-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2011.10.2.127.3h3cFcFLoginH3C-FC-FLOGIN-MIB
1.3.6.1.4.1.2011.10.2.127.3.1h3cFcFLoginMibObjectsH3C-FC-FLOGIN-MIB
1.3.6.1.4.1.2011.10.2.127.3.1.1h3cFcFLoginTableH3C-FC-FLOGIN-MIB
1.3.6.1.4.1.2011.10.2.127.3.1.1.1h3cFcFLoginEntryH3C-FC-FLOGIN-MIB
1.3.6.1.4.1.2011.10.2.127.3.1.1.1.9h3cFcFLoginSuppClassRequestedH3C-FC-FLOGIN-MIB