GDCMP7001-MIB :: mp7001TiminglossLocal

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › GDCMP7001-MIB › mp7001TiminglossLocal

mp7001TiminglossLocal

Module: GDCMP7001-MIB

OID (symbolic): GDCMP7001-MIB::mp7001TiminglossLocal

OID (numeric): 1.3.6.1.4.1.498.6.10.6.2.1.9

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Disables or enables the alarm on the Major buss or Minor buss.

What is mp7001TiminglossLocal?

Enables or disables reporting of a timing (clock) loss condition on this unit, and if enabled, routes it to either the shelf's Major or Minor alarm bus.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.498.6.10.6.2.1.9
snmpwalk -v2c -c public <target> GDCMP7001-MIB::mp7001TiminglossLocal

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.498.6.10.6.2.1.9.1
snmpget -v2c -c public <target> GDCMP7001-MIB::mp7001TiminglossLocal.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.498.6.10.6.2.1.9.1 i <value>

Start monitoring General DataComm (GDC) MP7001 multiport WAN access device with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the GDCMP7001-MIB::mp7001TiminglossLocal OID value, configure state conditions and alerts, and monitor any General DataComm (GDC) MP7001 multiport WAN access device from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.498gdcDMA200-MIB
1.3.6.1.4.1.498.6dsx1GDC-5553-MIB
Numeric OIDNameModule
1.3.6.1.4.1.498.6.10mp7001SystemGDCMP7001-MIB
1.3.6.1.4.1.498.6.10.6mp7001AlarmConfigGDCMP7001-MIB
1.3.6.1.4.1.498.6.10.6.2mp7001LocalAlarmConfigTableGDCMP7001-MIB
1.3.6.1.4.1.498.6.10.6.2.1mp7001LocalAlarmConfigEntryGDCMP7001-MIB
1.3.6.1.4.1.498.6.10.6.2.1.9mp7001TiminglossLocalGDCMP7001-MIB