G6-SYSTEM-MIB :: systemClimateLevel

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › G6-SYSTEM-MIB › systemClimateLevel

systemClimateLevel

Module: G6-SYSTEM-MIB

OID (symbolic): G6-SYSTEM-MIB::systemClimateLevel

OID (numeric): 1.3.6.1.4.1.3181.10.6.1.30.105

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Annotated temperature level.

What is systemClimateLevel?

An annotated interpretation of the raw temperature reading, from criticalLow(1) through normal(3) to criticalHigh(6) and shutdown(7) — lets monitoring dashboards alert on a human-readable thermal level rather than parsing a raw centigrade number.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.3181.10.6.1.30.105
snmpwalk -v2c -c public <target> G6-SYSTEM-MIB::systemClimateLevel

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.3181.10.6.1.30.105.1
snmpget -v2c -c public <target> G6-SYSTEM-MIB::systemClimateLevel.1

Start monitoring MICROSENS Generation 6 (G6) managed Ethernet switch (scripted operations/firmware/config-save history) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the G6-SYSTEM-MIB::systemClimateLevel OID value, configure state conditions and alerts, and monitor any MICROSENS Generation 6 (G6) managed Ethernet switch (scripted operations/firmware/config-save history) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.3181microsensMICROSENS-G6-MIB
1.3.6.1.4.1.3181.10managedSwitchesMICROSENS-G6-MIB
1.3.6.1.4.1.3181.10.6g6MICROSENS-G6-MIB
1.3.6.1.4.1.3181.10.6.1deviceG6-FACTORY-MIB
Numeric OIDNameModule
1.3.6.1.4.1.3181.10.6.1.30systemG6-SYSTEM-MIB
1.3.6.1.4.1.3181.10.6.1.30.105systemClimateLevelG6-SYSTEM-MIB