G6-POE-MIB :: energySuppliedLast5Seconds

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › G6-POE-MIB › energySuppliedLast5Seconds

energySuppliedLast5Seconds

Module: G6-POE-MIB

OID (symbolic): G6-POE-MIB::energySuppliedLast5Seconds

OID (numeric): 1.3.6.1.4.1.3181.10.6.1.33.102.1.2

Node type: OBJECT-TYPE

Type: Unsigned32

Access: read-only

Description: Energy supplied in the past 5 seconds. Value in joule.

What is energySuppliedLast5Seconds?

This read-only Unsigned32, in joules per its source description, reports the energy this PoE port supplied to its attached device over the most recent 5-second window, automatically updated at that interval. Admins use this very short window to see near-real-time power draw spikes from a connected device, useful when diagnosing a device that intermittently pulls a lot of power. For example, a brief jump in this 5-second figure coinciding with a device malfunction would help correlate the two events.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.3181.10.6.1.33.102.1.2
snmpwalk -v2c -c public <target> G6-POE-MIB::energySuppliedLast5Seconds

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.3181.10.6.1.33.102.1.2.1
snmpget -v2c -c public <target> G6-POE-MIB::energySuppliedLast5Seconds.1

Start monitoring MICROSENS Generation 6 (G6) managed Ethernet switch (Power over Ethernet) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the G6-POE-MIB::energySuppliedLast5Seconds OID value, configure state conditions and alerts, and monitor any MICROSENS Generation 6 (G6) managed Ethernet switch (Power over Ethernet) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.3181microsensMICROSENS-G6-MIB
1.3.6.1.4.1.3181.10managedSwitchesMICROSENS-G6-MIB
1.3.6.1.4.1.3181.10.6g6MICROSENS-G6-MIB
1.3.6.1.4.1.3181.10.6.1deviceG6-FACTORY-MIB
Numeric OIDNameModule
1.3.6.1.4.1.3181.10.6.1.33poeG6-POE-MIB
1.3.6.1.4.1.3181.10.6.1.33.102energySuppliedTableG6-POE-MIB
1.3.6.1.4.1.3181.10.6.1.33.102.1energySuppliedEntryG6-POE-MIB
1.3.6.1.4.1.3181.10.6.1.33.102.1.2energySuppliedLast5SecondsG6-POE-MIB