G6-MSP1000-MIB :: x2gConfigLossOfSignalHandling

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › G6-MSP1000-MIB › x2gConfigLossOfSignalHandling

x2gConfigLossOfSignalHandling

Module: G6-MSP1000-MIB

OID (symbolic): G6-MSP1000-MIB::x2gConfigLossOfSignalHandling

OID (numeric): 1.3.6.1.4.1.3181.10.6.1.94.3.1.12

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: When set to LOCAL a loss of input signal will not affect another port. When set to PERCOLATE, a loss of signal will turn off the transmitter of the currently associated port.

What is x2gConfigLossOfSignalHandling?

Determines what happens elsewhere on the X2G module when one port loses its input signal: LOCAL confines the fault to that port, while PERCOLATE also shuts off the transmitter of the port it is cross-connected to, propagating the fault so the far end also sees a clean loss-of-signal.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.3181.10.6.1.94.3.1.12
snmpwalk -v2c -c public <target> G6-MSP1000-MIB::x2gConfigLossOfSignalHandling

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.3181.10.6.1.94.3.1.12.1
snmpget -v2c -c public <target> G6-MSP1000-MIB::x2gConfigLossOfSignalHandling.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.3181.10.6.1.94.3.1.12.1 i <value>

Start monitoring MICROSENS MSP1000 modular media converter chassis with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the G6-MSP1000-MIB::x2gConfigLossOfSignalHandling OID value, configure state conditions and alerts, and monitor any MICROSENS MSP1000 modular media converter chassis from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.3181microsensMICROSENS-G6-MIB
1.3.6.1.4.1.3181.10managedSwitchesMICROSENS-G6-MIB
1.3.6.1.4.1.3181.10.6g6MICROSENS-G6-MIB
1.3.6.1.4.1.3181.10.6.1deviceG6-FACTORY-MIB
Numeric OIDNameModule
1.3.6.1.4.1.3181.10.6.1.94msp1000G6-MSP1000-MIB
1.3.6.1.4.1.3181.10.6.1.94.3x2gConfigTableG6-MSP1000-MIB
1.3.6.1.4.1.3181.10.6.1.94.3.1x2gConfigEntryG6-MSP1000-MIB
1.3.6.1.4.1.3181.10.6.1.94.3.1.12x2gConfigLossOfSignalHandlingG6-MSP1000-MIB