G6-MSP1000-MIB :: moduleControlSwitchOffBackup

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › G6-MSP1000-MIB › moduleControlSwitchOffBackup

moduleControlSwitchOffBackup

Module: G6-MSP1000-MIB

OID (symbolic): G6-MSP1000-MIB::moduleControlSwitchOffBackup

OID (numeric): 1.3.6.1.4.1.3181.10.6.1.94.12.1.6

Node type: OBJECT-TYPE

Type: DisplayString

Access: read-write

Description: For a module that supports backup and which currently is in backup condition this command will revert to normal operation. If this would disrupt traffic a warning is returned and nothing is executed. To override this warning and switch back nonetheless type switch_off_backup = CONFIRM

What is moduleControlSwitchOffBackup?

Reverts a module currently running on its backup path back to normal operation; if doing so would disrupt traffic the module returns a warning and does nothing unless the value CONFIRM is resent to force it through.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.3181.10.6.1.94.12.1.6
snmpwalk -v2c -c public <target> G6-MSP1000-MIB::moduleControlSwitchOffBackup

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.3181.10.6.1.94.12.1.6.1
snmpget -v2c -c public <target> G6-MSP1000-MIB::moduleControlSwitchOffBackup.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.3181.10.6.1.94.12.1.6.1 s <value>

Start monitoring MICROSENS MSP1000 modular media converter chassis with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the G6-MSP1000-MIB::moduleControlSwitchOffBackup OID value, configure state conditions and alerts, and monitor any MICROSENS MSP1000 modular media converter chassis from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.3181microsensMICROSENS-G6-MIB
1.3.6.1.4.1.3181.10managedSwitchesMICROSENS-G6-MIB
1.3.6.1.4.1.3181.10.6g6MICROSENS-G6-MIB
1.3.6.1.4.1.3181.10.6.1deviceG6-FACTORY-MIB
Numeric OIDNameModule
1.3.6.1.4.1.3181.10.6.1.94msp1000G6-MSP1000-MIB
1.3.6.1.4.1.3181.10.6.1.94.12moduleControlTableG6-MSP1000-MIB
1.3.6.1.4.1.3181.10.6.1.94.12.1moduleControlEntryG6-MSP1000-MIB
1.3.6.1.4.1.3181.10.6.1.94.12.1.6moduleControlSwitchOffBackupG6-MSP1000-MIB