G6-MSP1000-MIB :: moduleControlBertInsertError

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › G6-MSP1000-MIB › moduleControlBertInsertError

moduleControlBertInsertError

Module: G6-MSP1000-MIB

OID (symbolic): G6-MSP1000-MIB::moduleControlBertInsertError

OID (numeric): 1.3.6.1.4.1.3181.10.6.1.94.12.1.17

Node type: OBJECT-TYPE

Type: DisplayString

Access: read-write

Description: Inserts an error in the data pattern. This can be used to confirm that a BERT is actually operating. Only has an effect if a BERT is available on the module and configured to be active.

What is moduleControlBertInsertError?

Deliberately injects a single bit error into the BERT's test pattern, a quick way to confirm the tester is actually counting errors correctly; only has an effect if a BERT is present on the module and currently configured active.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.3181.10.6.1.94.12.1.17
snmpwalk -v2c -c public <target> G6-MSP1000-MIB::moduleControlBertInsertError

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.3181.10.6.1.94.12.1.17.1
snmpget -v2c -c public <target> G6-MSP1000-MIB::moduleControlBertInsertError.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.3181.10.6.1.94.12.1.17.1 s <value>

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> moduleControlBertInsertError.1

Start monitoring MICROSENS MSP1000 modular media converter chassis with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the G6-MSP1000-MIB::moduleControlBertInsertError OID value, configure state conditions and alerts, and monitor any MICROSENS MSP1000 modular media converter chassis from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.3181microsensMICROSENS-G6-MIB
1.3.6.1.4.1.3181.10managedSwitchesMICROSENS-G6-MIB
1.3.6.1.4.1.3181.10.6g6MICROSENS-G6-MIB
1.3.6.1.4.1.3181.10.6.1deviceG6-FACTORY-MIB
Numeric OIDNameModule
1.3.6.1.4.1.3181.10.6.1.94msp1000G6-MSP1000-MIB
1.3.6.1.4.1.3181.10.6.1.94.12moduleControlTableG6-MSP1000-MIB
1.3.6.1.4.1.3181.10.6.1.94.12.1moduleControlEntryG6-MSP1000-MIB
1.3.6.1.4.1.3181.10.6.1.94.12.1.17moduleControlBertInsertErrorG6-MSP1000-MIB