G6-MSP1000-MIB :: cxgConfigLossOfSignalHandling

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › G6-MSP1000-MIB › cxgConfigLossOfSignalHandling

cxgConfigLossOfSignalHandling

Module: G6-MSP1000-MIB

OID (symbolic): G6-MSP1000-MIB::cxgConfigLossOfSignalHandling

OID (numeric): 1.3.6.1.4.1.3181.10.6.1.94.6.1.8

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: When set to LOCAL a loss of input signal will not affect another port. When set to PERCOLATE, a loss of signal will turn off the transmitter of the other port.

What is cxgConfigLossOfSignalHandling?

Determines what happens elsewhere on the CXG module when one port loses its input signal: LOCAL confines the fault to that port, while PERCOLATE also shuts off the transmitter of the other port, propagating the fault so the far end also sees a clean loss-of-signal.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.3181.10.6.1.94.6.1.8
snmpwalk -v2c -c public <target> G6-MSP1000-MIB::cxgConfigLossOfSignalHandling

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.3181.10.6.1.94.6.1.8.1
snmpget -v2c -c public <target> G6-MSP1000-MIB::cxgConfigLossOfSignalHandling.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.3181.10.6.1.94.6.1.8.1 i <value>

Start monitoring MICROSENS MSP1000 modular media converter chassis with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the G6-MSP1000-MIB::cxgConfigLossOfSignalHandling OID value, configure state conditions and alerts, and monitor any MICROSENS MSP1000 modular media converter chassis from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.3181microsensMICROSENS-G6-MIB
1.3.6.1.4.1.3181.10managedSwitchesMICROSENS-G6-MIB
1.3.6.1.4.1.3181.10.6g6MICROSENS-G6-MIB
1.3.6.1.4.1.3181.10.6.1deviceG6-FACTORY-MIB
Numeric OIDNameModule
1.3.6.1.4.1.3181.10.6.1.94msp1000G6-MSP1000-MIB
1.3.6.1.4.1.3181.10.6.1.94.6cxgConfigTableG6-MSP1000-MIB
1.3.6.1.4.1.3181.10.6.1.94.6.1cxgConfigEntryG6-MSP1000-MIB
1.3.6.1.4.1.3181.10.6.1.94.6.1.8cxgConfigLossOfSignalHandlingG6-MSP1000-MIB