OID (symbolic): G6-EVENT-MIB::eventListCliScript

OID (numeric): 1.3.6.1.4.1.3181.10.6.3.70.1.1.13

Node type: OBJECT-TYPE

Type: DisplayString

Access: read-write

Description: When a script name is present the script will be executed whenever this event occurs. Note: Internal events do not trigger scripts even though a script name may be entered. Several scripts may be assigned to a single event. Syntax: app/scriptfile:subroutine para1 para2, next script... All fields besides the scriptfile are optional.

What is eventListCliScript?

This read-write DisplayString names one or more CLI scripts to execute automatically whenever this event occurs, using a syntax of app/scriptfile:subroutine plus optional parameters. Admins use it to trigger automated remediation or notification actions, such as running a script that pages someone, tied to a specific event, though internal events never trigger scripts even if one is configured. For example, an admin might set this to a notification script with a severity parameter so a paging script runs automatically whenever a critical event fires on that device.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.3181.10.6.3.70.1.1.13
snmpwalk -v2c -c public <target> G6-EVENT-MIB::eventListCliScript

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.3181.10.6.3.70.1.1.13.1
snmpget -v2c -c public <target> G6-EVENT-MIB::eventListCliScript.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.3181.10.6.3.70.1.1.13.1 s <value>

Start monitoring MICROSENS Generation 6 (G6) managed Ethernet switch (event log/alert configuration) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the G6-EVENT-MIB::eventListCliScript OID value, configure state conditions and alerts, and monitor any MICROSENS Generation 6 (G6) managed Ethernet switch (event log/alert configuration) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.3181microsensMICROSENS-G6-MIB
1.3.6.1.4.1.3181.10managedSwitchesMICROSENS-G6-MIB
1.3.6.1.4.1.3181.10.6g6MICROSENS-G6-MIB
1.3.6.1.4.1.3181.10.6.3managementG6-ACCESS-MIB
Numeric OIDNameModule
1.3.6.1.4.1.3181.10.6.3.70eventG6-EVENT-MIB
1.3.6.1.4.1.3181.10.6.3.70.1eventListTableG6-EVENT-MIB
1.3.6.1.4.1.3181.10.6.3.70.1.1eventListEntryG6-EVENT-MIB
1.3.6.1.4.1.3181.10.6.3.70.1.1.13eventListCliScriptG6-EVENT-MIB