Fore-TCM-MIB :: ecpAlarmReset

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › Fore-TCM-MIB › ecpAlarmReset

ecpAlarmReset

Module: Fore-TCM-MIB

OID (symbolic): Fore-TCM-MIB::ecpAlarmReset

OID (numeric): 1.3.6.1.4.1.326.2.2.1.7.1.3.1.1.1.5

Node type: OBJECT-TYPE

Type: Integer32

Access: read-write

Description: The manager may set this to the value zero to cancel a current alarm. This is useful for silencing alarms triggered via edge detection. If this variable is readable, then the alarm is resettable.

What is ecpAlarmReset?

Writing zero to this object cancels/silences the current alarm on this entry, useful for clearing an edge-triggered alarm; the object is only writable (resettable) if it's readable in the first place.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.326.2.2.1.7.1.3.1.1.1.5
snmpwalk -v2c -c public <target> Fore-TCM-MIB::ecpAlarmReset

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.326.2.2.1.7.1.3.1.1.1.5.1
snmpget -v2c -c public <target> Fore-TCM-MIB::ecpAlarmReset.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.326.2.2.1.7.1.3.1.1.1.5.1 i <value>

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> ecpAlarmReset.1

Start monitoring Fore Systems (later Marconi) ForeRunner ATM switch (ECP Timing Control Module hardware) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Fore-TCM-MIB::ecpAlarmReset OID value, configure state conditions and alerts, and monitor any Fore Systems (later Marconi) ForeRunner ATM switch (ECP Timing Control Module hardware) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.326foreCOMMON-GOLF-MIB
1.3.6.1.4.1.326.2systemsCOMMON-GOLF-MIB
1.3.6.1.4.1.326.2.2atmSwitchFore-Common-MIB
1.3.6.1.4.1.326.2.2.1hardwareFore-Common-MIB
Numeric OIDNameModule
1.3.6.1.4.1.326.2.2.1.7ecpStationModuleFore-TCM-MIB
1.3.6.1.4.1.326.2.2.1.7.1ecpHardwareFore-TCM-MIB
1.3.6.1.4.1.326.2.2.1.7.1.3ecpEnvironmentFore-TCM-MIB
1.3.6.1.4.1.326.2.2.1.7.1.3.1ecpAlarmGroupFore-TCM-MIB
1.3.6.1.4.1.326.2.2.1.7.1.3.1.1ecpAlarmTableFore-TCM-MIB
1.3.6.1.4.1.326.2.2.1.7.1.3.1.1.1ecpAlarmEntryFore-TCM-MIB
1.3.6.1.4.1.326.2.2.1.7.1.3.1.1.1.5ecpAlarmResetFore-TCM-MIB