Fore-Switch-MIB :: procUtilsNumMallocPart

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › Fore-Switch-MIB › procUtilsNumMallocPart

procUtilsNumMallocPart

Module: Fore-Switch-MIB

OID (symbolic): Fore-Switch-MIB::procUtilsNumMallocPart

OID (numeric): 1.3.6.1.4.1.326.2.2.1.1.1.3.1.9

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: The number of malloc partitions used on this SCP.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.326.2.2.1.1.1.3.1.9
snmpwalk -v2c -c public <target> Fore-Switch-MIB::procUtilsNumMallocPart

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.326.2.2.1.1.1.3.1.9.1
snmpget -v2c -c public <target> Fore-Switch-MIB::procUtilsNumMallocPart.1

Start monitoring Fore Systems (later Marconi) ForeRunner ATM switch (board/port/VPI-VCI inventory) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Fore-Switch-MIB::procUtilsNumMallocPart OID value, configure state conditions and alerts, and monitor any Fore Systems (later Marconi) ForeRunner ATM switch (board/port/VPI-VCI inventory) from a single console.

How to Use in IPNetwork Monitor

Select a Fore Systems (later Marconi) ForeRunner ATM switch as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type procUtilsNumMallocPart into the Find box to locate it in the OID tree, then select it and click OK. It reports the current number of malloc partitions in use on this switch control processor (SCP). On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an Integer32-type OID, Value bounds is the most useful condition here — trigger an alert if the count grows steadily over time without leveling off, since continuously rising memory-partition usage can indicate a memory leak. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.326foreCOMMON-GOLF-MIB
1.3.6.1.4.1.326.2systemsCOMMON-GOLF-MIB
1.3.6.1.4.1.326.2.2atmSwitchFore-Common-MIB
1.3.6.1.4.1.326.2.2.1hardwareFore-Common-MIB
1.3.6.1.4.1.326.2.2.1.1asxFore-Common-MIB
Numeric OIDNameModule
1.3.6.1.4.1.326.2.2.1.1.1boardGroupFore-Switch-MIB
1.3.6.1.4.1.326.2.2.1.1.1.3utilizationFore-Switch-MIB
1.3.6.1.4.1.326.2.2.1.1.1.3.1procUtilGroupFore-Switch-MIB
1.3.6.1.4.1.326.2.2.1.1.1.3.1.9procUtilsNumMallocPartFore-Switch-MIB