Fore-Sonet-Ext-MIB :: foreSonetVtDiagnosticsLabelValue

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › Fore-Sonet-Ext-MIB › foreSonetVtDiagnosticsLabelValue

foreSonetVtDiagnosticsLabelValue

Module: Fore-Sonet-Ext-MIB

OID (symbolic): Fore-Sonet-Ext-MIB::foreSonetVtDiagnosticsLabelValue

OID (numeric): 1.3.6.1.4.1.326.2.2.1.1.14.5.3.1.7

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Selects the label value to be transmitted in order to force PLM-V failures on the remote system.

What is foreSonetVtDiagnosticsLabelValue?

Selects which VT signal-label value is transmitted when foreSonetVtDiagnosticsLabel is set to on, choosing among unequipped, equipped-nonspecific, asynchronous, bit-synchronous, or byte-synchronous mappings. This lets an admin force a specific label to deliberately trigger a PLM-V failure for testing.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.326.2.2.1.1.14.5.3.1.7
snmpwalk -v2c -c public <target> Fore-Sonet-Ext-MIB::foreSonetVtDiagnosticsLabelValue

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.326.2.2.1.1.14.5.3.1.7.1
snmpget -v2c -c public <target> Fore-Sonet-Ext-MIB::foreSonetVtDiagnosticsLabelValue.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.326.2.2.1.1.14.5.3.1.7.1 i <value>

Start monitoring Fore Systems (later Marconi) ForeRunner ATM switch with SONET/SDH interfaces (extensions) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Fore-Sonet-Ext-MIB::foreSonetVtDiagnosticsLabelValue OID value, configure state conditions and alerts, and monitor any Fore Systems (later Marconi) ForeRunner ATM switch with SONET/SDH interfaces (extensions) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.326foreCOMMON-GOLF-MIB
1.3.6.1.4.1.326.2systemsCOMMON-GOLF-MIB
1.3.6.1.4.1.326.2.2atmSwitchFore-Common-MIB
1.3.6.1.4.1.326.2.2.1hardwareFore-Common-MIB
1.3.6.1.4.1.326.2.2.1.1asxFore-Common-MIB
Numeric OIDNameModule
1.3.6.1.4.1.326.2.2.1.1.14foreSonetMibFore-Sonet-Ext-MIB
1.3.6.1.4.1.326.2.2.1.1.14.5foreSonetVTFore-Sonet-Ext-MIB
1.3.6.1.4.1.326.2.2.1.1.14.5.3foreSonetVTDiagnosticsTableFore-Sonet-Ext-MIB
1.3.6.1.4.1.326.2.2.1.1.14.5.3.1foreSonetVTDiagnosticsEntryFore-Sonet-Ext-MIB
1.3.6.1.4.1.326.2.2.1.1.14.5.3.1.7foreSonetVtDiagnosticsLabelValueFore-Sonet-Ext-MIB