All MIBs › Fore-Sonet-Ext-MIB › foreSonetVtDiagnosticsLOP
foreSonetVtDiagnosticsLOP
Module: Fore-Sonet-Ext-MIB
OID (symbolic): Fore-Sonet-Ext-MIB::foreSonetVtDiagnosticsLOP
OID (numeric): 1.3.6.1.4.1.326.2.2.1.1.14.5.3.1.5
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: Controls the generation of VT LOP on the selected interface.
Value Description on(1) LOP is continually tramsmitted off(2) LOP is never transmitted momentary(3) LOP is transmitted for a short period of time.
What is foreSonetVtDiagnosticsLOP?
A test-mode control for VT Loss Of Pointer: on transmits it continually, off never transmits it (default), and momentary transmits it briefly. Used to verify downstream detection of a VT-level LOP condition.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.326.2.2.1.1.14.5.3.1.5 snmpwalk -v2c -c public <target> Fore-Sonet-Ext-MIB::foreSonetVtDiagnosticsLOP
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.326.2.2.1.1.14.5.3.1.5.1 snmpget -v2c -c public <target> Fore-Sonet-Ext-MIB::foreSonetVtDiagnosticsLOP.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.326.2.2.1.1.14.5.3.1.5.1 i <value>
Start monitoring Fore Systems (later Marconi) ForeRunner ATM switch with SONET/SDH interfaces (extensions) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Fore-Sonet-Ext-MIB::foreSonetVtDiagnosticsLOP OID value, configure state conditions and alerts, and monitor any Fore Systems (later Marconi) ForeRunner ATM switch with SONET/SDH interfaces (extensions) from a single console.
OID Breakdown
Upper-level ancestors (11 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.326 | fore | COMMON-GOLF-MIB |
| 1.3.6.1.4.1.326.2 | systems | COMMON-GOLF-MIB |
| 1.3.6.1.4.1.326.2.2 | atmSwitch | Fore-Common-MIB |
| 1.3.6.1.4.1.326.2.2.1 | hardware | Fore-Common-MIB |
| 1.3.6.1.4.1.326.2.2.1.1 | asx | Fore-Common-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.326.2.2.1.1.14 | foreSonetMib | Fore-Sonet-Ext-MIB |
| 1.3.6.1.4.1.326.2.2.1.1.14.5 | foreSonetVT | Fore-Sonet-Ext-MIB |
| 1.3.6.1.4.1.326.2.2.1.1.14.5.3 | foreSonetVTDiagnosticsTable | Fore-Sonet-Ext-MIB |
| 1.3.6.1.4.1.326.2.2.1.1.14.5.3.1 | foreSonetVTDiagnosticsEntry | Fore-Sonet-Ext-MIB |
| 1.3.6.1.4.1.326.2.2.1.1.14.5.3.1.5 | foreSonetVtDiagnosticsLOP | Fore-Sonet-Ext-MIB |