Fore-Sonet-Ext-MIB :: foreSonetSectionTotalBIPs

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › Fore-Sonet-Ext-MIB › foreSonetSectionTotalBIPs

foreSonetSectionTotalBIPs

Module: Fore-Sonet-Ext-MIB

OID (symbolic): Fore-Sonet-Ext-MIB::foreSonetSectionTotalBIPs

OID (numeric): 1.3.6.1.4.1.326.2.2.1.1.14.2.2.1.1

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description: The number of Section BIP-8 (Bit Interleaved Parity) errors that have been detected since the last time the port has been reset. The calculated BIP-8 code is compared with the BIP-8 code extracted from the B1 byte of the following frame. Differences indicate that a section level bit error has occurred.

What is foreSonetSectionTotalBIPs?

Counts Section-layer BIP-8 parity errors detected since the port was last reset, found by comparing the calculated B1 byte parity against the value received in the following frame. A rising count points to a physical-layer problem such as a bad fiber, dirty connector, or failing optic on this SONET section.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.326.2.2.1.1.14.2.2.1.1
snmpwalk -v2c -c public <target> Fore-Sonet-Ext-MIB::foreSonetSectionTotalBIPs

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.326.2.2.1.1.14.2.2.1.1.1
snmpget -v2c -c public <target> Fore-Sonet-Ext-MIB::foreSonetSectionTotalBIPs.1

Start monitoring Fore Systems (later Marconi) ForeRunner ATM switch with SONET/SDH interfaces (extensions) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Fore-Sonet-Ext-MIB::foreSonetSectionTotalBIPs OID value, configure state conditions and alerts, and monitor any Fore Systems (later Marconi) ForeRunner ATM switch with SONET/SDH interfaces (extensions) from a single console.

How to Use in IPNetwork Monitor

Select a Fore Systems (later Marconi) ForeRunner ATM switch with SONET/SDH interface (extensions) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type foreSonetSectionTotalBIPs into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. The number of Section BIP-8 (Bit Interleaved Parity) errors that have been detected since the last time the port has been reset. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases between polls, since a rising count of errors, failures, or discards often points to a real underlying problem. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.326foreCOMMON-GOLF-MIB
1.3.6.1.4.1.326.2systemsCOMMON-GOLF-MIB
1.3.6.1.4.1.326.2.2atmSwitchFore-Common-MIB
1.3.6.1.4.1.326.2.2.1hardwareFore-Common-MIB
1.3.6.1.4.1.326.2.2.1.1asxFore-Common-MIB
Numeric OIDNameModule
1.3.6.1.4.1.326.2.2.1.1.14foreSonetMibFore-Sonet-Ext-MIB
1.3.6.1.4.1.326.2.2.1.1.14.2foreSonetSectionFore-Sonet-Ext-MIB
1.3.6.1.4.1.326.2.2.1.1.14.2.2foreSonetSectionTotalTableFore-Sonet-Ext-MIB
1.3.6.1.4.1.326.2.2.1.1.14.2.2.1foreSonetSectionTotalEntryFore-Sonet-Ext-MIB
1.3.6.1.4.1.326.2.2.1.1.14.2.2.1.1foreSonetSectionTotalBIPsFore-Sonet-Ext-MIB