foreSonetPathDiagnosticsPREI

Module: Fore-Sonet-Ext-MIB

OID (symbolic): Fore-Sonet-Ext-MIB::foreSonetPathDiagnosticsPREI

OID (numeric): 1.3.6.1.4.1.326.2.2.1.1.14.4.4.1.4

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Controls the insertion of Sonet Path Remote Error
 Indication (REI_P) (previously called Far End Block Error 
 (FEBE)).

                        G1 byte
         1    2    3    4    5     6    7    8  
        ----|----|----|----|----|----|----|----|
        |     REI_P        |    RDI_P     | uu |
        ----------------------------------------

REI_P           Path Remote Error Indication
RDI_P           Path Remote Defect Indication
uu              Unused

off     When set to off, the value 0 is inserted in bits 
        1:4 of G1 byte.
on      When set to on, the value 0x8 is inserted in bits 
        1:4 of G1 byte.
auto    When set to auto, resume normal operation.

What is foreSonetPathDiagnosticsPREI?

A test-mode control for Path Remote Error Indication (formerly Path FEBE), encoded in bits 1-4 of the G1 byte: off always inserts 0 regardless of actual errors, on always inserts the maximum value (0x8), and auto (default) reports the real count. It's used to test a peer's handling of specific REI_P values.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.326.2.2.1.1.14.4.4.1.4
snmpwalk -v2c -c public <target> Fore-Sonet-Ext-MIB::foreSonetPathDiagnosticsPREI

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.326.2.2.1.1.14.4.4.1.4.1
snmpget -v2c -c public <target> Fore-Sonet-Ext-MIB::foreSonetPathDiagnosticsPREI.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.326.2.2.1.1.14.4.4.1.4.1 i <value>

Start monitoring Fore Systems (later Marconi) ForeRunner ATM switch with SONET/SDH interfaces (extensions) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Fore-Sonet-Ext-MIB::foreSonetPathDiagnosticsPREI OID value, configure state conditions and alerts, and monitor any Fore Systems (later Marconi) ForeRunner ATM switch with SONET/SDH interfaces (extensions) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.326foreCOMMON-GOLF-MIB
1.3.6.1.4.1.326.2systemsCOMMON-GOLF-MIB
1.3.6.1.4.1.326.2.2atmSwitchFore-Common-MIB
1.3.6.1.4.1.326.2.2.1hardwareFore-Common-MIB
1.3.6.1.4.1.326.2.2.1.1asxFore-Common-MIB
Numeric OIDNameModule
1.3.6.1.4.1.326.2.2.1.1.14foreSonetMibFore-Sonet-Ext-MIB
1.3.6.1.4.1.326.2.2.1.1.14.4foreSonetPathFore-Sonet-Ext-MIB
1.3.6.1.4.1.326.2.2.1.1.14.4.4foreSonetPathDiagnosticsTableFore-Sonet-Ext-MIB
1.3.6.1.4.1.326.2.2.1.1.14.4.4.1foreSonetPathDiagnosticsEntryFore-Sonet-Ext-MIB
1.3.6.1.4.1.326.2.2.1.1.14.4.4.1.4foreSonetPathDiagnosticsPREIFore-Sonet-Ext-MIB