All MIBs › Fore-Sonet-Ext-MIB › foreSonetLineDiagnosticsAPS
foreSonetLineDiagnosticsAPS
Module: Fore-Sonet-Ext-MIB
OID (symbolic): Fore-Sonet-Ext-MIB::foreSonetLineDiagnosticsAPS
OID (numeric): 1.3.6.1.4.1.326.2.2.1.1.14.3.3.1.3
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: Controls the insertion of line APS bytes (K1 and K2) that are determined by normal operating rules or by diagnostic mibs.
off When set to off, resume normal operation. on When set to on, K1 and K2 bytes are calculated by contents of diagnostic mibs.
What is foreSonetLineDiagnosticsAPS?
A test-mode control for the line's Automatic Protection Switching K1/K2 bytes: off (default) lets the K1/K2 values follow normal APS operating rules, on forces them to be computed from the values configured in the diagnostics MIB objects instead. It's used to exercise or validate specific APS byte sequences without waiting for a real protection-switching event.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.326.2.2.1.1.14.3.3.1.3 snmpwalk -v2c -c public <target> Fore-Sonet-Ext-MIB::foreSonetLineDiagnosticsAPS
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.326.2.2.1.1.14.3.3.1.3.1 snmpget -v2c -c public <target> Fore-Sonet-Ext-MIB::foreSonetLineDiagnosticsAPS.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.326.2.2.1.1.14.3.3.1.3.1 i <value>
Start monitoring Fore Systems (later Marconi) ForeRunner ATM switch with SONET/SDH interfaces (extensions) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Fore-Sonet-Ext-MIB::foreSonetLineDiagnosticsAPS OID value, configure state conditions and alerts, and monitor any Fore Systems (later Marconi) ForeRunner ATM switch with SONET/SDH interfaces (extensions) from a single console.
OID Breakdown
Upper-level ancestors (11 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.326 | fore | COMMON-GOLF-MIB |
| 1.3.6.1.4.1.326.2 | systems | COMMON-GOLF-MIB |
| 1.3.6.1.4.1.326.2.2 | atmSwitch | Fore-Common-MIB |
| 1.3.6.1.4.1.326.2.2.1 | hardware | Fore-Common-MIB |
| 1.3.6.1.4.1.326.2.2.1.1 | asx | Fore-Common-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.326.2.2.1.1.14 | foreSonetMib | Fore-Sonet-Ext-MIB |
| 1.3.6.1.4.1.326.2.2.1.1.14.3 | foreSonetLine | Fore-Sonet-Ext-MIB |
| 1.3.6.1.4.1.326.2.2.1.1.14.3.3 | foreSonetLineDiagnosticsTable | Fore-Sonet-Ext-MIB |
| 1.3.6.1.4.1.326.2.2.1.1.14.3.3.1 | foreSonetLineDiagnosticsEntry | Fore-Sonet-Ext-MIB |
| 1.3.6.1.4.1.326.2.2.1.1.14.3.3.1.3 | foreSonetLineDiagnosticsAPS | Fore-Sonet-Ext-MIB |