All MIBs › Fore-Sonet-Ext-MIB › foreSonetLineBipThrSeconds
foreSonetLineBipThrSeconds
Module: Fore-Sonet-Ext-MIB
OID (symbolic): Fore-Sonet-Ext-MIB::foreSonetLineBipThrSeconds
OID (numeric): 1.3.6.1.4.1.326.2.2.1.1.14.3.1.1.2
Node type: OBJECT-TYPE
Type: Integer32
Access: read-write
Description: This variable represents the consecutive number of BAD/GOOD seconds to detect/clear a B2 byte Line Bit Interleaved Parity (BIP) Defect. The range of the values it can take is between 2 and 10 inclusive.
What is foreSonetLineBipThrSeconds?
Sets the number of consecutive bad or good seconds (range 2-10, default 10) needed to declare or clear a B2-byte Line BIP defect. Raising it makes the defect declaration less sensitive to brief error bursts, useful for avoiding false alarms on a noisy but still serviceable line.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.326.2.2.1.1.14.3.1.1.2 snmpwalk -v2c -c public <target> Fore-Sonet-Ext-MIB::foreSonetLineBipThrSeconds
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.326.2.2.1.1.14.3.1.1.2.1 snmpget -v2c -c public <target> Fore-Sonet-Ext-MIB::foreSonetLineBipThrSeconds.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.326.2.2.1.1.14.3.1.1.2.1 i <value>
Start monitoring Fore Systems (later Marconi) ForeRunner ATM switch with SONET/SDH interfaces (extensions) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Fore-Sonet-Ext-MIB::foreSonetLineBipThrSeconds OID value, configure state conditions and alerts, and monitor any Fore Systems (later Marconi) ForeRunner ATM switch with SONET/SDH interfaces (extensions) from a single console.
OID Breakdown
Upper-level ancestors (11 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.326 | fore | COMMON-GOLF-MIB |
| 1.3.6.1.4.1.326.2 | systems | COMMON-GOLF-MIB |
| 1.3.6.1.4.1.326.2.2 | atmSwitch | Fore-Common-MIB |
| 1.3.6.1.4.1.326.2.2.1 | hardware | Fore-Common-MIB |
| 1.3.6.1.4.1.326.2.2.1.1 | asx | Fore-Common-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.326.2.2.1.1.14 | foreSonetMib | Fore-Sonet-Ext-MIB |
| 1.3.6.1.4.1.326.2.2.1.1.14.3 | foreSonetLine | Fore-Sonet-Ext-MIB |
| 1.3.6.1.4.1.326.2.2.1.1.14.3.1 | foreSonetLineConfigTable | Fore-Sonet-Ext-MIB |
| 1.3.6.1.4.1.326.2.2.1.1.14.3.1.1 | foreSonetLineConfigEntry | Fore-Sonet-Ext-MIB |
| 1.3.6.1.4.1.326.2.2.1.1.14.3.1.1.2 | foreSonetLineBipThrSeconds | Fore-Sonet-Ext-MIB |