Fore-Sonet-Ext-MIB :: foreSonetLineBipFailEnable

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › Fore-Sonet-Ext-MIB › foreSonetLineBipFailEnable

foreSonetLineBipFailEnable

Module: Fore-Sonet-Ext-MIB

OID (symbolic): Fore-Sonet-Ext-MIB::foreSonetLineBipFailEnable

OID (numeric): 1.3.6.1.4.1.326.2.2.1.1.14.3.1.1.4

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: This variable controls whether declaration of a Line BIP Defect forces the port's operState to Down.

What is foreSonetLineBipFailEnable?

Controls whether a declared Line BIP Defect is allowed to force this port's operational state to Down: enabled lets it bring the port down, disabled keeps the port up despite the defect. Admins may disable this on a link that's chronically noisy but still passing traffic, to avoid unwanted flapping.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.326.2.2.1.1.14.3.1.1.4
snmpwalk -v2c -c public <target> Fore-Sonet-Ext-MIB::foreSonetLineBipFailEnable

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.326.2.2.1.1.14.3.1.1.4.1
snmpget -v2c -c public <target> Fore-Sonet-Ext-MIB::foreSonetLineBipFailEnable.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.326.2.2.1.1.14.3.1.1.4.1 i <value>

Start monitoring Fore Systems (later Marconi) ForeRunner ATM switch with SONET/SDH interfaces (extensions) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Fore-Sonet-Ext-MIB::foreSonetLineBipFailEnable OID value, configure state conditions and alerts, and monitor any Fore Systems (later Marconi) ForeRunner ATM switch with SONET/SDH interfaces (extensions) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.326foreCOMMON-GOLF-MIB
1.3.6.1.4.1.326.2systemsCOMMON-GOLF-MIB
1.3.6.1.4.1.326.2.2atmSwitchFore-Common-MIB
1.3.6.1.4.1.326.2.2.1hardwareFore-Common-MIB
1.3.6.1.4.1.326.2.2.1.1asxFore-Common-MIB
Numeric OIDNameModule
1.3.6.1.4.1.326.2.2.1.1.14foreSonetMibFore-Sonet-Ext-MIB
1.3.6.1.4.1.326.2.2.1.1.14.3foreSonetLineFore-Sonet-Ext-MIB
1.3.6.1.4.1.326.2.2.1.1.14.3.1foreSonetLineConfigTableFore-Sonet-Ext-MIB
1.3.6.1.4.1.326.2.2.1.1.14.3.1.1foreSonetLineConfigEntryFore-Sonet-Ext-MIB
1.3.6.1.4.1.326.2.2.1.1.14.3.1.1.4foreSonetLineBipFailEnableFore-Sonet-Ext-MIB