foreSonetLineBerErrorModel

Module: Fore-Sonet-Ext-MIB

OID (symbolic): Fore-Sonet-Ext-MIB::foreSonetLineBerErrorModel

OID (numeric): 1.3.6.1.4.1.326.2.2.1.1.14.3.1.1.7

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: This is the error distribution model to be used to identify signal degrade and signal fail conditions. errorModelRandom selects a random error distribution and declares signal conditions based on the thresholds set in sonetLineSignalDegradeBer and sonetLineSignalFailBer. errorModelBurst selects a burst error model and declares signal degrade conditions based on the thresholds set in sonetLineBipThrSeconds and sonetLineBipThrErrors. errorModelNone disables detection of signal conditions.

What is foreSonetLineBerErrorModel?

Selects which model the port uses to evaluate bit error rate and declare signal degrade/fail conditions: errorModelRandom applies the thresholds in foreSonetLineSignalDegradeBer and foreSonetLineSignalFailBer, errorModelBurst instead uses the burst thresholds in foreSonetLineBipThrSeconds and foreSonetLineBipThrErrors, and errorModelNone disables this detection entirely. Choosing the model that matches the expected error pattern of the transmission medium avoids both false alarms and missed degradations.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.326.2.2.1.1.14.3.1.1.7
snmpwalk -v2c -c public <target> Fore-Sonet-Ext-MIB::foreSonetLineBerErrorModel

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.326.2.2.1.1.14.3.1.1.7.1
snmpget -v2c -c public <target> Fore-Sonet-Ext-MIB::foreSonetLineBerErrorModel.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.326.2.2.1.1.14.3.1.1.7.1 i <value>

Start monitoring Fore Systems (later Marconi) ForeRunner ATM switch with SONET/SDH interfaces (extensions) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Fore-Sonet-Ext-MIB::foreSonetLineBerErrorModel OID value, configure state conditions and alerts, and monitor any Fore Systems (later Marconi) ForeRunner ATM switch with SONET/SDH interfaces (extensions) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.326foreCOMMON-GOLF-MIB
1.3.6.1.4.1.326.2systemsCOMMON-GOLF-MIB
1.3.6.1.4.1.326.2.2atmSwitchFore-Common-MIB
1.3.6.1.4.1.326.2.2.1hardwareFore-Common-MIB
1.3.6.1.4.1.326.2.2.1.1asxFore-Common-MIB
Numeric OIDNameModule
1.3.6.1.4.1.326.2.2.1.1.14foreSonetMibFore-Sonet-Ext-MIB
1.3.6.1.4.1.326.2.2.1.1.14.3foreSonetLineFore-Sonet-Ext-MIB
1.3.6.1.4.1.326.2.2.1.1.14.3.1foreSonetLineConfigTableFore-Sonet-Ext-MIB
1.3.6.1.4.1.326.2.2.1.1.14.3.1.1foreSonetLineConfigEntryFore-Sonet-Ext-MIB
1.3.6.1.4.1.326.2.2.1.1.14.3.1.1.7foreSonetLineBerErrorModelFore-Sonet-Ext-MIB