Fore-DSX1-MIB :: dsx1ForeFramingLOSs

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › Fore-DSX1-MIB › dsx1ForeFramingLOSs

dsx1ForeFramingLOSs

Module: Fore-DSX1-MIB

OID (symbolic): Fore-DSX1-MIB::dsx1ForeFramingLOSs

OID (numeric): 1.3.6.1.4.1.326.2.2.1.1.10.2.1.1.2

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description: The number of secondsx in which Loss Of Signal (LOS) errors have been detected.

What is dsx1ForeFramingLOSs?

Counts the number of seconds in which Loss Of Signal was detected on this port, a key indicator an admin checks first when a T1/E1 circuit appears completely dead.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.326.2.2.1.1.10.2.1.1.2
snmpwalk -v2c -c public <target> Fore-DSX1-MIB::dsx1ForeFramingLOSs

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.326.2.2.1.1.10.2.1.1.2.1
snmpget -v2c -c public <target> Fore-DSX1-MIB::dsx1ForeFramingLOSs.1

Start monitoring Fore Systems (later Marconi) ForeRunner ATM switch (T1/E1 DSX1 WAN interface module) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Fore-DSX1-MIB::dsx1ForeFramingLOSs OID value, configure state conditions and alerts, and monitor any Fore Systems (later Marconi) ForeRunner ATM switch (T1/E1 DSX1 WAN interface module) from a single console.

How to Use in IPNetwork Monitor

Select a Fore Systems (later Marconi) ForeRunner ATM switch (T1/E1 DSX1 WAN interface module) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type dsx1ForeFramingLOSs into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. The number of secondsx in which Loss Of Signal (LOS) errors have been detected. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases between polls, since a rising count of errors, failures, or discards often points to a real underlying problem. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.326foreCOMMON-GOLF-MIB
1.3.6.1.4.1.326.2systemsCOMMON-GOLF-MIB
1.3.6.1.4.1.326.2.2atmSwitchFore-Common-MIB
1.3.6.1.4.1.326.2.2.1hardwareFore-Common-MIB
1.3.6.1.4.1.326.2.2.1.1asxFore-Common-MIB
Numeric OIDNameModule
1.3.6.1.4.1.326.2.2.1.1.10foreDsx1Fore-DSX1-MIB
1.3.6.1.4.1.326.2.2.1.1.10.2dsx1ForeStatsGroupFore-DSX1-MIB
1.3.6.1.4.1.326.2.2.1.1.10.2.1dsx1ForeFramingTableFore-DSX1-MIB
1.3.6.1.4.1.326.2.2.1.1.10.2.1.1dsx1ForeFramingEntryFore-DSX1-MIB
1.3.6.1.4.1.326.2.2.1.1.10.2.1.1.2dsx1ForeFramingLOSsFore-DSX1-MIB