All MIBs › FUJITSU-EXTENDED-NONOS-AWN-MIB-V06 › awnSysLineMegalink
awnSysLineMegalink
Module: FUJITSU-EXTENDED-NONOS-AWN-MIB-V06
OID (symbolic): FUJITSU-EXTENDED-NONOS-AWN-MIB-V06::awnSysLineMegalink
OID (numeric): 1.3.6.1.4.1.211.1.127.29.1.4.1.1.5
Node type: OBJECT-TYPE
Type: OCTET STRING
Access: read-only
Description: Megalink status
What is awnSysLineMegalink?
A 256-byte OCTET STRING carrying 'Megalink' (Fujitsu's proprietary multiplexed trunk) status for the same indexed line entry. An operator would check this when troubleshooting the aggregated trunk carrying multiple channels over that unit/card/port.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.211.1.127.29.1.4.1.1.5 snmpwalk -v2c -c public <target> FUJITSU-EXTENDED-NONOS-AWN-MIB-V06::awnSysLineMegalink
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.211.1.127.29.1.4.1.1.5.1 snmpget -v2c -c public <target> FUJITSU-EXTENDED-NONOS-AWN-MIB-V06::awnSysLineMegalink.1
SNMPv3 example:
snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> awnSysLineMegalink.1
Start monitoring Fujitsu AWN embedded/non-OS network equipment with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the FUJITSU-EXTENDED-NONOS-AWN-MIB-V06::awnSysLineMegalink OID value, configure state conditions and alerts, and monitor any Fujitsu AWN embedded/non-OS network equipment from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.211 | fujitsu | Alert-Definition-Originator-MIB |
| 1.3.6.1.4.1.211.1 | product | CFAB-MIB |
| 1.3.6.1.4.1.211.1.127 | nonos | CFAB-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.211.1.127.29 | awn | FUJITSU-EXTENDED-NONOS-AWN-MIB-V06 |
| 1.3.6.1.4.1.211.1.127.29.1 | awnSystem | FUJITSU-EXTENDED-NONOS-AWN-MIB-V06 |
| 1.3.6.1.4.1.211.1.127.29.1.4 | awnSysLine | FUJITSU-EXTENDED-NONOS-AWN-MIB-V06 |
| 1.3.6.1.4.1.211.1.127.29.1.4.1 | awnSysLineTable | FUJITSU-EXTENDED-NONOS-AWN-MIB-V06 |
| 1.3.6.1.4.1.211.1.127.29.1.4.1.1 | awnSysLineEntry | FUJITSU-EXTENDED-NONOS-AWN-MIB-V06 |