FRNETSERV-MIB :: frMgtVCSigUserLinkRelErrors

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsFRNETSERV-MIBfrMgtVCSigUserLinkRelErrors

frMgtVCSigUserLinkRelErrors

Module: FRNETSERV-MIB

OID (symbolic): FRNETSERV-MIB::frMgtVCSigUserLinkRelErrors

OID (numeric): 1.3.6.1.2.1.10.44.1.2.1.11

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description: The number of user-side local in-channel signaling link reliability errors (i.e., non- receipt of Status/Status Enquiry messages or invalid sequence numbers in a Link Integrity Verification Information Element) for this UNI/NNI logical port. If the logical port is not

performing user-side procedures, then this object is not instantiated.

What is frMgtVCSigUserLinkRelErrors?

Counts user-side link-reliability errors on this port's signaling channel, such as missed status/status-enquiry messages or bad sequence numbers. A rising count points to an unreliable physical or data-link layer under the frame relay signaling.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.2.1.10.44.1.2.1.11
snmpwalk -v2c -c public <target> FRNETSERV-MIB::frMgtVCSigUserLinkRelErrors

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.2.1.10.44.1.2.1.11.1
snmpget -v2c -c public <target> FRNETSERV-MIB::frMgtVCSigUserLinkRelErrors.1

Start monitoring Vendor-neutral Frame Relay-capable router/WAN switch, any manufacturer (RFC 2954) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the FRNETSERV-MIB::frMgtVCSigUserLinkRelErrors OID value, configure state conditions and alerts, and monitor any Vendor-neutral Frame Relay-capable router/WAN switch, any manufacturer (RFC 2954) from a single console.

How to Use in IPNetwork Monitor

Select a device implementing FRNETSERV-MIB as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type frMgtVCSigUserLinkRelErrors into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. The number of user-side local in-channel signaling link reliability errors (i.e., non- receipt of Status/Status Enquiry messages or invalid sequence numbers in a Link Integrity Verification Information Element) for this UNI/NNI logical port. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases between polls, since a rising count of errors, failures, or discards often points to a real underlying problem. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.2mgmtAXON-MIB
1.3.6.1.2.1mib_2AXON-MIB
1.3.6.1.2.1.10transmissionCHECKPOINT-MIB-2
Numeric OIDNameModule
1.3.6.1.2.1.10.44frnetservMIBFRNETSERV-MIB
1.3.6.1.2.1.10.44.1frnetservObjectsFRNETSERV-MIB
1.3.6.1.2.1.10.44.1.2frMgtVCSigTableFRNETSERV-MIB
1.3.6.1.2.1.10.44.1.2.1frMgtVCSigEntryFRNETSERV-MIB
1.3.6.1.2.1.10.44.1.2.1.11frMgtVCSigUserLinkRelErrorsFRNETSERV-MIB