frLportVCSigProtocol
Module: FRNETSERV-MIB
OID (symbolic): FRNETSERV-MIB::frLportVCSigProtocol
OID (numeric): 1.3.6.1.2.1.10.44.1.1.1.6
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: The value of this object identifies the Local In-Channel Signaling Protocol that is used for this frame relay UNI/NNI logical port.
none(1): Interface does not use a PVC signaling protocol
lmi(2): Interface operates the Stratacom/ Nortel/DEC Local Management Interface Specification protocol
ansiT1617D(3): Interface operates the ANSI T1.617 Annex D PVC status protocol
ansiT1617B(4): Interface operates the ANSI T1.617 Annex B procedures
ccittQ933A(5): Interface operates the ITU Q.933 Annex A PVC status protocol
What is frLportVCSigProtocol?
Identifies which Local In-Channel Signaling protocol is actually running on this Frame Relay port: none, LMI, ANSI T1.617 Annex D, ANSI T1.617 Annex B, or ITU Q.933 Annex A. Compare this to frLportVCSigProtocolAdmin to confirm the desired signaling protocol actually took effect.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.2.1.10.44.1.1.1.6 snmpwalk -v2c -c public <target> FRNETSERV-MIB::frLportVCSigProtocol
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.2.1.10.44.1.1.1.6.1 snmpget -v2c -c public <target> FRNETSERV-MIB::frLportVCSigProtocol.1
Start monitoring Vendor-neutral Frame Relay-capable router/WAN switch, any manufacturer (RFC 2954) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the FRNETSERV-MIB::frLportVCSigProtocol OID value, configure state conditions and alerts, and monitor any Vendor-neutral Frame Relay-capable router/WAN switch, any manufacturer (RFC 2954) from a single console.
OID Breakdown
Upper-level ancestors (7 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.2 | mgmt | AXON-MIB |
| 1.3.6.1.2.1 | mib_2 | AXON-MIB |
| 1.3.6.1.2.1.10 | transmission | CHECKPOINT-MIB-2 |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.2.1.10.44 | frnetservMIB | FRNETSERV-MIB |
| 1.3.6.1.2.1.10.44.1 | frnetservObjects | FRNETSERV-MIB |
| 1.3.6.1.2.1.10.44.1.1 | frLportTable | FRNETSERV-MIB |
| 1.3.6.1.2.1.10.44.1.1.1 | frLportEntry | FRNETSERV-MIB |
| 1.3.6.1.2.1.10.44.1.1.1.6 | frLportVCSigProtocol | FRNETSERV-MIB |