All MIBs › FRAME-RELAY-DTE-SVC-MIB › frSvcOutCIR
frSvcOutCIR
Module: FRAME-RELAY-DTE-SVC-MIB
OID (symbolic): FRAME-RELAY-DTE-SVC-MIB::frSvcOutCIR
OID (numeric): 1.3.6.1.2.1.10.32.7.1.2.1.17
Node type: OBJECT-TYPE
Type: Integer32
Access: read-write
Description: CIR is the average number of 'Frame Re- lay Information Field' bits transferred per second across a user network interface from the calling user, measured over the measurement inter- val. The default value is 0.
What is frSvcOutCIR?
Sets the Committed Information Rate (CIR) for the outbound leg, the average bits-per-second the network guarantees to transfer toward the called user (default 0), the send-side counterpart to frSvcInCIR.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.2.1.10.32.7.1.2.1.17 snmpwalk -v2c -c public <target> FRAME-RELAY-DTE-SVC-MIB::frSvcOutCIR
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.2.1.10.32.7.1.2.1.17.1 snmpget -v2c -c public <target> FRAME-RELAY-DTE-SVC-MIB::frSvcOutCIR.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.2.1.10.32.7.1.2.1.17.1 i <value>
Start monitoring Frame Relay routers/DTE devices with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the FRAME-RELAY-DTE-SVC-MIB::frSvcOutCIR OID value, configure state conditions and alerts, and monitor any Frame Relay routers/DTE devices from a single console.
OID Breakdown
Upper-level ancestors (8 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.2 | mgmt | APERTUS-NPG-MIB |
| 1.3.6.1.2.1 | mib_2 | AXON-MIB |
| 1.3.6.1.2.1.10 | transmission | CHECKPOINT-MIB-2 |
| 1.3.6.1.2.1.10.32 | frameRelayDTE | FRAME-RELAY-DTE-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.2.1.10.32.7 | frameRelayDteSvc | FRAME-RELAY-DTE-SVC-MIB |
| 1.3.6.1.2.1.10.32.7.1 | frDteSvc | FRAME-RELAY-DTE-SVC-MIB |
| 1.3.6.1.2.1.10.32.7.1.2 | frSvcTable | FRAME-RELAY-DTE-SVC-MIB |
| 1.3.6.1.2.1.10.32.7.1.2.1 | frSvcEntry | FRAME-RELAY-DTE-SVC-MIB |
| 1.3.6.1.2.1.10.32.7.1.2.1.17 | frSvcOutCIR | FRAME-RELAY-DTE-SVC-MIB |