FOUNDRY-SN-SWITCH-GROUP-MIB :: snSwIfStatsInUtilization

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsFOUNDRY-SN-SWITCH-GROUP-MIBsnSwIfStatsInUtilization

snSwIfStatsInUtilization

Module: FOUNDRY-SN-SWITCH-GROUP-MIB

OID (symbolic): FOUNDRY-SN-SWITCH-GROUP-MIB::snSwIfStatsInUtilization

OID (numeric): 1.3.6.1.4.1.1991.1.1.3.3.5.1.52

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: The input network utilization in hundredths of a percent over a 5 minutes interval.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1991.1.1.3.3.5.1.52
snmpwalk -v2c -c public <target> FOUNDRY-SN-SWITCH-GROUP-MIB::snSwIfStatsInUtilization

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1991.1.1.3.3.5.1.52.1
snmpget -v2c -c public <target> FOUNDRY-SN-SWITCH-GROUP-MIB::snSwIfStatsInUtilization.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> snSwIfStatsInUtilization.1

Start monitoring Brocade/Foundry FastIron/BigIron Ethernet switch (VLAN/FDB/STP) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the FOUNDRY-SN-SWITCH-GROUP-MIB::snSwIfStatsInUtilization OID value, configure state conditions and alerts, and monitor any Brocade/Foundry FastIron/BigIron Ethernet switch (VLAN/FDB/STP) from a single console.

How to Use in IPNetwork Monitor

Select a Brocade/Foundry FastIron/BigIron Ethernet switch as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type snSwIfStatsInUtilization into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. It reports the input network utilization on this interface, in hundredths of a percent, averaged over a 5-minute interval. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an INTEGER-type OID, Value bounds is the most useful condition here — trigger an alert if utilization exceeds 80%, since sustained high inbound utilization often precedes latency and packet loss. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1991foundryFOUNDRY-SN-ROOT-MIB
1.3.6.1.4.1.1991.1productsFOUNDRY-SN-ROOT-MIB
1.3.6.1.4.1.1991.1.1switchFOUNDRY-SN-ROOT-MIB
1.3.6.1.4.1.1991.1.1.3snSwitchFOUNDRY-SN-ROOT-MIB
Numeric OIDNameModule
1.3.6.1.4.1.1991.1.1.3.3snSwPortInfoFOUNDRY-SN-SWITCH-GROUP-MIB
1.3.6.1.4.1.1991.1.1.3.3.5snSwIfInfoTableFOUNDRY-SN-SWITCH-GROUP-MIB
1.3.6.1.4.1.1991.1.1.3.3.5.1snSwIfInfoEntryFOUNDRY-SN-SWITCH-GROUP-MIB
1.3.6.1.4.1.1991.1.1.3.3.5.1.52snSwIfStatsInUtilizationFOUNDRY-SN-SWITCH-GROUP-MIB