All MIBs › FIBRE-CHANNEL-MGMT-MIB › fcConnUnitControl
fcConnUnitControl
Module: FIBRE-CHANNEL-MGMT-MIB
OID (symbolic): FIBRE-CHANNEL-MGMT-MIB::fcConnUnitControl
OID (numeric): 1.3.6.1.2.1.8888.1.1.3.1.20
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: This object is used to control the addressed connectivity unit.
NOTE: 'ColdStart' and 'WarmStart' are as defined in mib-2 and are not meant to be a factory reset.
resetConnUnitColdStart: the addressed unit performs a 'ColdStart' reset.
resetConnUnitWarmStart: the addressed unit performs a 'WarmStart' reset.
offlineConnUnit: the addressed unit puts itself into an implementation dependant 'offline' state. In general,if a unit is in an offline state, it cannot be used to perform meaningful Fibre Channel work.
onlineConnUnit: the addressed unit puts itself into an implementation dependant 'online' state. In general, if a unit is in an online state, it is capable of performing meaningful Fibre Channel work.
NOTE: Each implementation may chose not to support SNMP Set operations for any or all of these values. For Sets specifying varbinds for instances of this object and values not supported by a given implementation, the agent will return the SNMP WrongValue PDU error code.
What is fcConnUnitControl?
A write-only command object used to remotely control this connectivity unit: cold-start or warm-start reset it, or take it offline or back online; support for any particular value is implementation-dependent, and an unsupported set returns a WrongValue error.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.2.1.8888.1.1.3.1.20 snmpwalk -v2c -c public <target> FIBRE-CHANNEL-MGMT-MIB::fcConnUnitControl
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.2.1.8888.1.1.3.1.20.1 snmpget -v2c -c public <target> FIBRE-CHANNEL-MGMT-MIB::fcConnUnitControl.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.2.1.8888.1.1.3.1.20.1 i <value>
Start monitoring Vendor-neutral Fibre Channel switch/HBA, any manufacturer (RFC 4044) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the FIBRE-CHANNEL-MGMT-MIB::fcConnUnitControl OID value, configure state conditions and alerts, and monitor any Vendor-neutral Fibre Channel switch/HBA, any manufacturer (RFC 4044) from a single console.
OID Breakdown
Upper-level ancestors (6 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.2 | mgmt | APERTUS-NPG-MIB |
| 1.3.6.1.2.1 | mib_2 | AXON-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.2.1.8888 | fcMgmtMIB | FIBRE-CHANNEL-MGMT-MIB |
| 1.3.6.1.2.1.8888.1 | fcMgmtObjects | FIBRE-CHANNEL-MGMT-MIB |
| 1.3.6.1.2.1.8888.1.1 | fcMgmtConfig | FIBRE-CHANNEL-MGMT-MIB |
| 1.3.6.1.2.1.8888.1.1.3 | fcConnUnitTable | FIBRE-CHANNEL-MGMT-MIB |
| 1.3.6.1.2.1.8888.1.1.3.1 | fcConnUnitEntry | FIBRE-CHANNEL-MGMT-MIB |
| 1.3.6.1.2.1.8888.1.1.3.1.20 | fcConnUnitControl | FIBRE-CHANNEL-MGMT-MIB |