All MIBs › EdgeSwitch-QOS-ISCSI-MIB › agentIscsiFlowAccelerationConnectionCID
agentIscsiFlowAccelerationConnectionCID
Module: EdgeSwitch-QOS-ISCSI-MIB
OID (symbolic): EdgeSwitch-QOS-ISCSI-MIB::agentIscsiFlowAccelerationConnectionCID
OID (numeric): 1.3.6.1.4.1.4413.1.1.3.5.4.1.6
Node type: OBJECT-TYPE
Type: Unsigned32
Access: read-only
Description: The iSCSI CID for this connection.
What is agentIscsiFlowAccelerationConnectionCID?
This read-only Unsigned32 reports the iSCSI Connection ID assigned to this specific TCP connection within its session. The CID distinguishes multiple TCP connections that belong to the same multi-connection iSCSI session, letting an admin see how many parallel connections a session is using. An admin verifying that multi-connection iSCSI is actually load-balancing across links might see two connection rows with different agentIscsiFlowAccelerationConnectionCID values but the same session index.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.4413.1.1.3.5.4.1.6 snmpwalk -v2c -c public <target> EdgeSwitch-QOS-ISCSI-MIB::agentIscsiFlowAccelerationConnectionCID
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.4413.1.1.3.5.4.1.6.1 snmpget -v2c -c public <target> EdgeSwitch-QOS-ISCSI-MIB::agentIscsiFlowAccelerationConnectionCID.1
Start monitoring Ubiquiti EdgeSwitch (Broadcom FastPath-based) switch (iSCSI Flow Acceleration QoS) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the EdgeSwitch-QOS-ISCSI-MIB::agentIscsiFlowAccelerationConnectionCID OID value, configure state conditions and alerts, and monitor any Ubiquiti EdgeSwitch (Broadcom FastPath-based) switch (iSCSI Flow Acceleration QoS) from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.4413 | broadcom | BASP-Config-MIB |
| 1.3.6.1.4.1.4413.1 | enet | BASP-Config-MIB |
| 1.3.6.1.4.1.4413.1.1 | fastPath | EdgeSwitch-REF-MIB |
| 1.3.6.1.4.1.4413.1.1.3 | fastPathQOS | EdgeSwitch-QOS-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.4413.1.1.3.5 | fastPathIscsiFlowAcceleration | EdgeSwitch-QOS-ISCSI-MIB |
| 1.3.6.1.4.1.4413.1.1.3.5.4 | agentIscsiFlowAccelerationConnectionTable | EdgeSwitch-QOS-ISCSI-MIB |
| 1.3.6.1.4.1.4413.1.1.3.5.4.1 | agentIscsiFlowAccelerationConnectionEntry | EdgeSwitch-QOS-ISCSI-MIB |
| 1.3.6.1.4.1.4413.1.1.3.5.4.1.6 | agentIscsiFlowAccelerationConnectionCID | EdgeSwitch-QOS-ISCSI-MIB |