All MIBs › EdgeSwitch-QOS-AUTOVOIP-MIB › agentAutoVoIPProtocolTcOrRemarkValue
agentAutoVoIPProtocolTcOrRemarkValue
Module: EdgeSwitch-QOS-AUTOVOIP-MIB
OID (symbolic): EdgeSwitch-QOS-AUTOVOIP-MIB::agentAutoVoIPProtocolTcOrRemarkValue
OID (numeric): 1.3.6.1.4.1.4413.1.1.3.4.1.4
Node type: OBJECT-TYPE
Type: Unsigned32
Access: read-write
Description: If 'agentAutoVoIPProtocolPriScheme' is traffic class, then the object 'agentAutoVoIPProtocolTcOrRemarkValue' is CoS Queue value to which all VoIP traffic is mapped to.
if 'agentAutoVoIPProtocolPriScheme' is remark, then the object 'agentAutoVoIPProtocolTcOrRemarkValue' is 802.1p priority to which all VoIP traffic is remarked at the ingress port. This is used by Protocol based Auto VoIP
What is agentAutoVoIPProtocolTcOrRemarkValue?
This read-write value, ranging 0-7, is interpreted either as a CoS queue number when agentAutoVoIPProtocolPriScheme is set to trafficClass, or as an 802.1p priority value used to remark ingress VoIP traffic when the scheme is set to remark. An admin sets it to control exactly which priority level protocol-detected VoIP traffic receives, depending on which scheme was chosen. For example, with the scheme set to remark, setting this value to 5 causes ingress VoIP packets to be remarked with 802.1p priority 5.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.4413.1.1.3.4.1.4 snmpwalk -v2c -c public <target> EdgeSwitch-QOS-AUTOVOIP-MIB::agentAutoVoIPProtocolTcOrRemarkValue
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.4413.1.1.3.4.1.4.1 snmpget -v2c -c public <target> EdgeSwitch-QOS-AUTOVOIP-MIB::agentAutoVoIPProtocolTcOrRemarkValue.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.4413.1.1.3.4.1.4.1 i <value>
Start monitoring Ubiquiti EdgeSwitch (Broadcom FastPath-based) switch (Auto-VoIP QoS) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the EdgeSwitch-QOS-AUTOVOIP-MIB::agentAutoVoIPProtocolTcOrRemarkValue OID value, configure state conditions and alerts, and monitor any Ubiquiti EdgeSwitch (Broadcom FastPath-based) switch (Auto-VoIP QoS) from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.4413 | broadcom | BASP-Config-MIB |
| 1.3.6.1.4.1.4413.1 | enet | BASP-Config-MIB |
| 1.3.6.1.4.1.4413.1.1 | fastPath | EdgeSwitch-REF-MIB |
| 1.3.6.1.4.1.4413.1.1.3 | fastPathQOS | EdgeSwitch-QOS-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.4413.1.1.3.4 | fastPathQOSAUTOVOIP | EdgeSwitch-QOS-AUTOVOIP-MIB |
| 1.3.6.1.4.1.4413.1.1.3.4.1 | agentAutoVoIPCfgGroup | EdgeSwitch-QOS-AUTOVOIP-MIB |
| 1.3.6.1.4.1.4413.1.1.3.4.1.4 | agentAutoVoIPProtocolTcOrRemarkValue | EdgeSwitch-QOS-AUTOVOIP-MIB |