EdgeSwitch-POWER-ETHERNET-MIB :: agentPethPowerDetectionType

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › EdgeSwitch-POWER-ETHERNET-MIB › agentPethPowerDetectionType

agentPethPowerDetectionType

Module: EdgeSwitch-POWER-ETHERNET-MIB

OID (symbolic): EdgeSwitch-POWER-ETHERNET-MIB::agentPethPowerDetectionType

OID (numeric): 1.3.6.1.4.1.4413.1.1.15.1.1.1.8

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Describes PD detection mechanism performed by the PSE port. A value of none(0) means no detection is done. A value of legacy(1) means only legacy capacitive detection scheme is used. A value of 4ptdot3afonly(2) means that IEEE 802.3af 4point detection scheme is used. A value of 4ptdot3afandlegacy(3) means that IEEE 802.3af 4point detection scheme is used and when that fails to detect a connected PD, legacity capacitive detection is used. A value of 2ptdot3afonly(4) means that IEEE 802.3af 2point detection scheme is used. A value of 2ptdot3afandlegacy(5)means that IEEE 802.3af 2point detection scheme is used and when that fails to detect a connected PD, legacity capacitive detection is used. The value 'none' can not be forcibly set by the administrator.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.4413.1.1.15.1.1.1.8
snmpwalk -v2c -c public <target> EdgeSwitch-POWER-ETHERNET-MIB::agentPethPowerDetectionType

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.4413.1.1.15.1.1.1.8.1
snmpget -v2c -c public <target> EdgeSwitch-POWER-ETHERNET-MIB::agentPethPowerDetectionType.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.4413.1.1.15.1.1.1.8.1 i <value>

Start monitoring Ubiquiti EdgeSwitch PoE switch (extended PoE/PoE+ hardware reporting) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the EdgeSwitch-POWER-ETHERNET-MIB::agentPethPowerDetectionType OID value, configure state conditions and alerts, and monitor any Ubiquiti EdgeSwitch PoE switch (extended PoE/PoE+ hardware reporting) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.4413broadcomBASP-Config-MIB
1.3.6.1.4.1.4413.1enetBASP-Config-MIB
1.3.6.1.4.1.4413.1.1fastPathEdgeSwitch-REF-MIB
Numeric OIDNameModule
1.3.6.1.4.1.4413.1.1.15fastPathpowerEthernetMIBEdgeSwitch-POWER-ETHERNET-MIB
1.3.6.1.4.1.4413.1.1.15.1agentPethObjectsEdgeSwitch-POWER-ETHERNET-MIB
1.3.6.1.4.1.4413.1.1.15.1.1agentPethPsePortTableEdgeSwitch-POWER-ETHERNET-MIB
1.3.6.1.4.1.4413.1.1.15.1.1.1agentPethPsePortEntryEdgeSwitch-POWER-ETHERNET-MIB
1.3.6.1.4.1.4413.1.1.15.1.1.1.8agentPethPowerDetectionTypeEdgeSwitch-POWER-ETHERNET-MIB