EXTREME-SLB-MIB :: extremeSlbRealAppUp

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › EXTREME-SLB-MIB › extremeSlbRealAppUp

extremeSlbRealAppUp

Module: EXTREME-SLB-MIB

OID (symbolic): EXTREME-SLB-MIB::extremeSlbRealAppUp

OID (numeric): 1.3.6.1.4.1.1916.1.14.2.1.3

Node type: OBJECT-TYPE

Type: TruthValue

Access: read-write

Description: Indicates whether the application is operational. If the application is up, the load balancer may send traffic to it. If the application is not up, the load balancer will send no traffic to it, but the load balancer may send traffic to other applications on the same server.

What is extremeSlbRealAppUp?

This TruthValue setting indicates whether a specific application (such as a particular service or listening port) on a backend real server is operational, which is more granular than extremeSlbRealServerUp since a server can be up while one of its applications on it has failed. An administrator or health-check integration sets this to false to stop the load balancer sending traffic destined for that one application, while the load balancer can still send traffic for the server's other, still-healthy applications. For example, if a server's database service crashes but its web service is fine, only the database application's entry would be set to false, leaving web traffic flowing normally.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1916.1.14.2.1.3
snmpwalk -v2c -c public <target> EXTREME-SLB-MIB::extremeSlbRealAppUp

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1916.1.14.2.1.3.1
snmpget -v2c -c public <target> EXTREME-SLB-MIB::extremeSlbRealAppUp.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.1916.1.14.2.1.3.1 s <value>

Start monitoring Extreme Networks Ethernet switch, Layer 4 load-balancing deployment (Server Load Balancing) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the EXTREME-SLB-MIB::extremeSlbRealAppUp OID value, configure state conditions and alerts, and monitor any Extreme Networks Ethernet switch, Layer 4 load-balancing deployment (Server Load Balancing) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1916extremeA3COM51-SS9000SX
1.3.6.1.4.1.1916.1extremeAgentEXTREME-BASE-MIB
1.3.6.1.4.1.1916.1.14extremeSlbEXTREME-BASE-MIB
Numeric OIDNameModule
1.3.6.1.4.1.1916.1.14.2extremeSlbRealAppTableEXTREME-SLB-MIB
1.3.6.1.4.1.1916.1.14.2.1extremeSlbRealAppEntryEXTREME-SLB-MIB
1.3.6.1.4.1.1916.1.14.2.1.3extremeSlbRealAppUpEXTREME-SLB-MIB