All MIBs › EXALINK-FUSION-MIB › fusionFanSensorValue
fusionFanSensorValue
Module: EXALINK-FUSION-MIB
OID (symbolic): EXALINK-FUSION-MIB::fusionFanSensorValue
OID (numeric): 1.3.6.1.4.1.43296.3.2.2.1.3
Node type: OBJECT-TYPE
Type: Integer32
Access: read-only
Description: Current reading of fan sensor
What is fusionFanSensorValue?
The current fan speed, in RPM, for this fan - a value dropping toward zero indicates a failed or stalled fan.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.43296.3.2.2.1.3 snmpwalk -v2c -c public <target> EXALINK-FUSION-MIB::fusionFanSensorValue
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.43296.3.2.2.1.3.1 snmpget -v2c -c public <target> EXALINK-FUSION-MIB::fusionFanSensorValue.1
Start monitoring Exablaze ExaLink Fusion chassis switch with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the EXALINK-FUSION-MIB::fusionFanSensorValue OID value, configure state conditions and alerts, and monitor any Exablaze ExaLink Fusion chassis switch from a single console.
OID Breakdown
Upper-level ancestors (6 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.43296.3 | exaFusion | EXALINK-FUSION-MIB |
| 1.3.6.1.4.1.43296.3.2 | fusionSensor | EXALINK-FUSION-MIB |
| 1.3.6.1.4.1.43296.3.2.2 | fusionFanSensorTable | EXALINK-FUSION-MIB |
| 1.3.6.1.4.1.43296.3.2.2.1 | fusionFanSensor | EXALINK-FUSION-MIB |
| 1.3.6.1.4.1.43296.3.2.2.1.3 | fusionFanSensorValue | EXALINK-FUSION-MIB |