ENGENIUS-STATUS-MIB :: cbCurrentTxRate

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › ENGENIUS-STATUS-MIB › cbCurrentTxRate

cbCurrentTxRate

Module: ENGENIUS-STATUS-MIB

OID (symbolic): ENGENIUS-STATUS-MIB::cbCurrentTxRate

OID (numeric): 1.3.6.1.4.1.14125.3.1.3

Node type: OBJECT-TYPE

Type: OCTET STRING

Access: read-only

Description: The transmit bit rates operated, corresponding to data rates from 1 Mb/s to 54 Mb/s.

What is cbCurrentTxRate?

The data rate the client bridge is currently transmitting at, anywhere from 1 Mb/s up to 54 Mb/s. A rate stuck near the bottom of that range usually points to a poor RF link rather than a wired problem downstream.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.14125.3.1.3
snmpwalk -v2c -c public <target> ENGENIUS-STATUS-MIB::cbCurrentTxRate

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.14125.3.1.3.1
snmpget -v2c -c public <target> ENGENIUS-STATUS-MIB::cbCurrentTxRate.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> cbCurrentTxRate.1

Start monitoring EnGenius (Senao) wireless access point or bridge with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ENGENIUS-STATUS-MIB::cbCurrentTxRate OID value, configure state conditions and alerts, and monitor any EnGenius (Senao) wireless access point or bridge from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.14125engeniusENGENIUS-CLIENT-MIB
Numeric OIDNameModule
1.3.6.1.4.1.14125.3engeniusstatusENGENIUS-STATUS-MIB
1.3.6.1.4.1.14125.3.1wirelessCBStatusENGENIUS-STATUS-MIB
1.3.6.1.4.1.14125.3.1.3cbCurrentTxRateENGENIUS-STATUS-MIB