ELTEX-MES-CPU-TASKS-UTIL-MIB :: eltCpuTasksUtilStatisticsUtilizationDuringLast5Minutes

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › ELTEX-MES-CPU-TASKS-UTIL-MIB › eltCpuTasksUtilStatisticsUtilizationDuringLast5Minutes

eltCpuTasksUtilStatisticsUtilizationDuringLast5Minutes

Module: ELTEX-MES-CPU-TASKS-UTIL-MIB

OID (symbolic): ELTEX-MES-CPU-TASKS-UTIL-MIB::eltCpuTasksUtilStatisticsUtilizationDuringLast5Minutes

OID (numeric): 1.3.6.1.4.1.35265.1.23.1.9.1.2.1.1.5

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Percentage of the device CPU task utilization during the last 5 minutes. The value 101 is a dummy value, indicating that the CPU tasks utilization was not measured (since measurement is disabled or was disabled during last 5 minutes).

What is eltCpuTasksUtilStatisticsUtilizationDuringLast5Minutes?

This object reports a task's CPU utilization percentage averaged over the last 5 minutes, with 101 indicating measurement was not enabled. This still-longer window helps admins spot a task that is steadily consuming CPU over time rather than reacting only to momentary spikes. For example, a sustained value of 40 here alongside similarly elevated 1-minute and 5-second readings points to a genuinely overloaded task rather than a one-off burst.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.35265.1.23.1.9.1.2.1.1.5
snmpwalk -v2c -c public <target> ELTEX-MES-CPU-TASKS-UTIL-MIB::eltCpuTasksUtilStatisticsUtilizationDuringLast5Minutes

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.35265.1.23.1.9.1.2.1.1.5.1
snmpget -v2c -c public <target> ELTEX-MES-CPU-TASKS-UTIL-MIB::eltCpuTasksUtilStatisticsUtilizationDuringLast5Minutes.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> eltCpuTasksUtilStatisticsUtilizationDuringLast5Minutes.1

Start monitoring Eltex MES-series Ethernet switch (per-task CPU utilization) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ELTEX-MES-CPU-TASKS-UTIL-MIB::eltCpuTasksUtilStatisticsUtilizationDuringLast5Minutes OID value, configure state conditions and alerts, and monitor any Eltex MES-series Ethernet switch (per-task CPU utilization) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.35265eltexLtdELTEX-SMI-ACTUAL
1.3.6.1.4.1.35265.1elHardwareELTEX-SMI-ACTUAL
1.3.6.1.4.1.35265.1.23eltMesELTEX-MES
1.3.6.1.4.1.35265.1.23.1eltMesMngELTEX-MES
1.3.6.1.4.1.35265.1.23.1.9eltMesCpuTasksUtilMIBELTEX-MES-MNG-MIB
Numeric OIDNameModule
1.3.6.1.4.1.35265.1.23.1.9.1eltMesCpuTasksUtilObjectsELTEX-MES-CPU-TASKS-UTIL-MIB
1.3.6.1.4.1.35265.1.23.1.9.1.2eltMesCpuTasksUtilStatisticsELTEX-MES-CPU-TASKS-UTIL-MIB
1.3.6.1.4.1.35265.1.23.1.9.1.2.1eltCpuTasksUtilStatisticsTableELTEX-MES-CPU-TASKS-UTIL-MIB
1.3.6.1.4.1.35265.1.23.1.9.1.2.1.1eltCpuTasksUtilStatisticsEntryELTEX-MES-CPU-TASKS-UTIL-MIB
1.3.6.1.4.1.35265.1.23.1.9.1.2.1.1.5eltCpuTasksUtilStatisticsUtilizationDuringLast5MinutesELTEX-MES-CPU-TASKS-UTIL-MIB