eltdot1sMstpMultiProcessInstanceEnable

Module: ELTEX-MES-BRIDGE-STP-MULTIPROCESS-MIB

OID (symbolic): ELTEX-MES-BRIDGE-STP-MULTIPROCESS-MIB::eltdot1sMstpMultiProcessInstanceEnable

OID (numeric): 1.3.6.1.4.1.35265.1.23.1.401.0.2.2.1.1.3

Node type: OBJECT-TYPE

Type: TruthValue

Access: read-only

Description: Specifies whether this Instance is STP enable or disable

What is eltdot1sMstpMultiProcessInstanceEnable?

This true/false flag reports whether Spanning Tree is currently enabled for this MST instance within its process. An engineer checks it to confirm an instance is actually protecting its mapped VLANs rather than sitting disabled.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.35265.1.23.1.401.0.2.2.1.1.3
snmpwalk -v2c -c public <target> ELTEX-MES-BRIDGE-STP-MULTIPROCESS-MIB::eltdot1sMstpMultiProcessInstanceEnable

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.35265.1.23.1.401.0.2.2.1.1.3.1
snmpget -v2c -c public <target> ELTEX-MES-BRIDGE-STP-MULTIPROCESS-MIB::eltdot1sMstpMultiProcessInstanceEnable.1

Start monitoring Eltex MES-series Ethernet switch (multi-instance STP/MSTP) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ELTEX-MES-BRIDGE-STP-MULTIPROCESS-MIB::eltdot1sMstpMultiProcessInstanceEnable OID value, configure state conditions and alerts, and monitor any Eltex MES-series Ethernet switch (multi-instance STP/MSTP) from a single console.

OID Breakdown

Upper-level ancestors (12 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.35265eltexLtdELTEX-SMI-ACTUAL
1.3.6.1.4.1.35265.1elHardwareELTEX-SMI-ACTUAL
1.3.6.1.4.1.35265.1.23eltMesELTEX-MES
1.3.6.1.4.1.35265.1.23.1eltMesMngELTEX-MES
1.3.6.1.4.1.35265.1.23.1.401eltMesBridgeExtMIBELTEX-MES-MNG-MIB
1.3.6.1.4.1.35265.1.23.1.401.0eltMesBridgeExtMIBObjectsELTEX-MES-BRIDGE-EXT-MIB
Numeric OIDNameModule
1.3.6.1.4.1.35265.1.23.1.401.0.2eltMesStpMultiProcessMIBELTEX-MES-BRIDGE-STP-MULTIPROCESS-MIB
1.3.6.1.4.1.35265.1.23.1.401.0.2.2eltMesDot1sMstpMultiProcessELTEX-MES-BRIDGE-STP-MULTIPROCESS-MIB
1.3.6.1.4.1.35265.1.23.1.401.0.2.2.1eltdot1sMstpMultiProcessInstanceTableELTEX-MES-BRIDGE-STP-MULTIPROCESS-MIB
1.3.6.1.4.1.35265.1.23.1.401.0.2.2.1.1eltdot1sMstpMultiProcessInstanceEntryELTEX-MES-BRIDGE-STP-MULTIPROCESS-MIB
1.3.6.1.4.1.35265.1.23.1.401.0.2.2.1.1.3eltdot1sMstpMultiProcessInstanceEnableELTEX-MES-BRIDGE-STP-MULTIPROCESS-MIB