EFM-CU-MIB :: efmCuPmeDeviceFaultEnable

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsEFM-CU-MIBefmCuPmeDeviceFaultEnable

efmCuPmeDeviceFaultEnable

Module: EFM-CU-MIB

OID (symbolic): EFM-CU-MIB::efmCuPmeDeviceFaultEnable

OID (numeric): 1.3.6.1.2.1.167.1.2.1.1.8

Node type: OBJECT-TYPE

Type: TruthValue

Access: read-write

Description: Indicates whether efmCuPmeDeviceFault notifications

should be generated for this interface.

A value of true(1) indicates that efmCuPmeDeviceFault notification is enabled. A value of false(2) indicates that the notification is disabled.

What is efmCuPmeDeviceFaultEnable?

This read-write boolean controls whether an efmCuPmeDeviceFault notification is sent when a vendor-specific diagnostic or self-test detects a fault on this PME. Enable it if you want proactive alerts for hardware-level problems on individual copper-pair modems rather than discovering them only through link-down events.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.2.1.167.1.2.1.1.8
snmpwalk -v2c -c public <target> EFM-CU-MIB::efmCuPmeDeviceFaultEnable

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.2.1.167.1.2.1.1.8.1
snmpget -v2c -c public <target> EFM-CU-MIB::efmCuPmeDeviceFaultEnable.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.2.1.167.1.2.1.1.8.1 s <value>

Start monitoring DSLAM/EFM access multiplexer or CPE (802.3ah EFM Copper, vendor-neutral IETF standard) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the EFM-CU-MIB::efmCuPmeDeviceFaultEnable OID value, configure state conditions and alerts, and monitor any DSLAM/EFM access multiplexer or CPE (802.3ah EFM Copper, vendor-neutral IETF standard) from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.2mgmtAXON-MIB
1.3.6.1.2.1mib_2AXON-MIB
Numeric OIDNameModule
1.3.6.1.2.1.167efmCuMIBEFM-CU-MIB
1.3.6.1.2.1.167.1efmCuObjectsEFM-CU-MIB
1.3.6.1.2.1.167.1.2efmCuPmeEFM-CU-MIB
1.3.6.1.2.1.167.1.2.1efmCuPmeConfTableEFM-CU-MIB
1.3.6.1.2.1.167.1.2.1.1efmCuPmeConfEntryEFM-CU-MIB
1.3.6.1.2.1.167.1.2.1.1.8efmCuPmeDeviceFaultEnableEFM-CU-MIB