dvmrpRouteUpTime

Module: DVMRP-STD-MIB

OID (symbolic): DVMRP-STD-MIB::dvmrpRouteUpTime

OID (numeric): 1.3.6.1.3.62.1.1.4.1.7

Node type: OBJECT-TYPE

Type: TimeTicks

Access: read-only

Description: The time since the route represented by this entry was learned by the router.

What is dvmrpRouteUpTime?

How long, in timeticks, since this DVMRP route was first learned by the router — useful for judging route stability versus recent churn.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.3.62.1.1.4.1.7
snmpwalk -v2c -c public <target> DVMRP-STD-MIB::dvmrpRouteUpTime

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.3.62.1.1.4.1.7.1
snmpget -v2c -c public <target> DVMRP-STD-MIB::dvmrpRouteUpTime.1

Start monitoring DVMRP-capable multicast router (vendor-neutral IETF standard) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the DVMRP-STD-MIB::dvmrpRouteUpTime OID value, configure state conditions and alerts, and monitor any DVMRP-capable multicast router (vendor-neutral IETF standard) from a single console.

How to Use in IPNetwork Monitor

Select a DVMRP-capable multicast router (vendor-neutral IETF standard) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type dvmrpRouteUpTime into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. It reports how long this DVMRP multicast route has been known by the router. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a TimeTicks-type OID, Value bounds is the most useful condition here — trigger an alert if the value resets to a low number unexpectedly, since that indicates the route was lost and relearned. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.3experimentalAXON-MIB
1.3.6.1.3.62dvmrpMIBDVMRP-MIB
1.3.6.1.3.62.1dvmrpMIBObjectsDVMRP-MIB
1.3.6.1.3.62.1.1dvmrpDVMRP-MIB
1.3.6.1.3.62.1.1.4dvmrpNeighborTableDVMRP-MIB
1.3.6.1.3.62.1.1.4.1dvmrpNeighborEntryDVMRP-MIB
Numeric OIDNameModule
1.3.6.1.3.62.1.1.4.1.7dvmrpRouteUpTimeDVMRP-STD-MIB