DOT3-OAM-MIB :: dot3OamErrSymPeriodWindowLo

MIB Reference — IPNetwork Monitor

All MIBsDOT3-OAM-MIBdot3OamErrSymPeriodWindowLo

dot3OamErrSymPeriodWindowLo

Module: DOT3-OAM-MIB

OID (symbolic): DOT3-OAM-MIB::dot3OamErrSymPeriodWindowLo

OID (numeric): 1.3.6.1.2.1.158.1.5.1.2

Node type: OBJECT-TYPE

Type: Unsigned32

Access: read-write

Description:

The two objects dot3OamErrSymPeriodWindowHi and dot3OamErrSymPeriodWindowLo together form an unsigned 64-bit integer representing the number of symbols over which this threshold event is defined. This is defined as

dot3OamErrSymPeriodWindow = ((2^32)*dot3OamErrSymPeriodWindowHi) + dot3OamErrSymPeriodWindowLo

If dot3OamErrSymPeriodThreshold symbol errors occur within a window of dot3OamErrSymPeriodWindow symbols, an Event Notification OAMPDU should be generated with an Errored Symbol Period Event TLV indicating that the threshold has been crossed in this window.

The default value for dot3OamErrSymPeriodWindow is the number of symbols in one second for the underlying physical layer.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.2.1.158.1.5.1.2
snmpwalk -v2c -c public <target> DOT3-OAM-MIB::dot3OamErrSymPeriodWindowLo

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.2.1.158.1.5.1.2.1
snmpget -v2c -c public <target> DOT3-OAM-MIB::dot3OamErrSymPeriodWindowLo.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.2.1.158.1.5.1.2.1 i <value>

OID Breakdown

Numeric OIDNameModule
1isoLANART-AGENT
1.3orgBIANCA-BRICK-PPP-MIB
1.3.6dodBIANCA-BRICK-PPP-MIB
1.3.6.1internetBIANCA-BRICK-PPP-MIB
1.3.6.1.2mgmtBKTEL-HFC862-BASE-MIB
1.3.6.1.2.1mib_2CHECKPOINT-MIB-2
1.3.6.1.2.1.158dot3OamMIBDOT3-OAM-MIB
1.3.6.1.2.1.158.1dot3OamObjectsDOT3-OAM-MIB
1.3.6.1.2.1.158.1.5dot3OamEventConfigTableDOT3-OAM-MIB
1.3.6.1.2.1.158.1.5.1dot3OamEventConfigEntryDOT3-OAM-MIB
1.3.6.1.2.1.158.1.5.1.2dot3OamErrSymPeriodWindowLoDOT3-OAM-MIB