catvSwitch

Module: DKT-CATV-MIB

OID (symbolic): DKT-CATV-MIB::catvSwitch

OID (numeric): 1.3.6.1.4.1.27304.11.2

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Switch CATV module on or off. 1 = on 0 = off

What is catvSwitch?

This read-write INTEGER turns the DKT device's CATV (cable television) module on or off, with the source specifying that a value of 1 means on and 0 means off. An administrator would set this object to enable or disable the CATV signal path on the device, for example to shut it down during maintenance or to reactivate cable TV distribution after servicing. For example, writing the value 0 to this object would switch off the CATV module, while writing 1 would turn it back on.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.27304.11.2
snmpwalk -v2c -c public <target> DKT-CATV-MIB::catvSwitch

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.27304.11.2.1
snmpget -v2c -c public <target> DKT-CATV-MIB::catvSwitch.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.27304.11.2.1 i <value>

Start monitoring DKT A/S CATV headend and distribution equipment with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the DKT-CATV-MIB::catvSwitch OID value, configure state conditions and alerts, and monitor any DKT A/S CATV headend and distribution equipment from a single console.

How to Use in IPNetwork Monitor

Select a DKT A/S CATV headend and distribution equipment as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type catvSwitch into the Find box to locate it in the OID tree, then select it and click OK. It reports the switch CATV module on or off. 1 = on 0 = off. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an INTEGER-type OID, Value bounds is the most useful condition here — trigger an alert if the value is anything other than '1 (on)', since that indicates the condition this object reports has changed to one worth investigating. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.27304dktDKT-MIB
Numeric OIDNameModule
1.3.6.1.4.1.27304.11catvMIBDKT-CATV-MIB
1.3.6.1.4.1.27304.11.2catvSwitchDKT-CATV-MIB