swL2DevInfoFrontPanelLedStatus

Module: DES3028P-L2MGMT-MIB

OID (symbolic): DES3028P-L2MGMT-MIB::swL2DevInfoFrontPanelLedStatus

OID (numeric): 1.3.6.1.4.1.171.11.63.7.2.1.1.5

Node type: OBJECT-TYPE

Type: OCTET STRING

Access: read-only

Description: This object is a set of system LED indications.

When log in system DES3028/DES3052 which do not support POE, the first two octets is defined as system LED. The first LED is power LED. The second LED is console LED.

When log in system DES3028p/DES3052p which support POE, the first four octets are defined as system LED. The first octet is 0x02 and the second octet is 0x01 when in normal mode. Contrarily, the first octet is 0x01 and the second octet is 0x02 when in poe mode. The third octet indicates the power LED. The fourth octet indicates the console LED.

The other octets are defined as follow:

start on the third or fifth octets separately correspond to system support poe or system which does not support poe indicate the logical port LED (following swL2BasePort ordering). Every two bytes are presented to a port. The first byte is presentd to the Link/Activity LED. The second byte is presented to the Speed LED.

Link/Activity LED :

The most significant bit is used for blink/solid: 8 = The LED blinks.

The second significant bit is used for link status:

1 = link fail.

2 = link pass.

Speed LED :

01 = 10Mbps.

02 = 100Mbps.

03 = 1000Mbps.

The four remaining bits are currently unused and must be 0.

What is swL2DevInfoFrontPanelLedStatus?

A read-only byte string that mirrors the state of the switch's front-panel LEDs: the first octets carry the system LEDs (power and console, plus a normal/PoE mode pair on the PoE models DES3028P/DES3052P), and every following pair of octets describes one port's Link/Activity LED and Speed LED in swL2BasePort order. An admin can poll it to see remotely whether a port LED is blinking or solid and whether the link is up, for example when someone on site reports an LED color and you want to cross-check it.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.171.11.63.7.2.1.1.5
snmpwalk -v2c -c public <target> DES3028P-L2MGMT-MIB::swL2DevInfoFrontPanelLedStatus

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.171.11.63.7.2.1.1.5.1
snmpget -v2c -c public <target> DES3028P-L2MGMT-MIB::swL2DevInfoFrontPanelLedStatus.1

Start monitoring D-Link DES-3028P managed switch with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the DES3028P-L2MGMT-MIB::swL2DevInfoFrontPanelLedStatus OID value, configure state conditions and alerts, and monitor any D-Link DES-3028P managed switch from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.171d_linkDE1500-MIB
1.3.6.1.4.1.171.11dlink_mgmtDES2218-MIB
1.3.6.1.4.1.171.11.63des30xxSeriesProdDLINK-SWPRIMGMT-MIB
1.3.6.1.4.1.171.11.63.7des3028pSWPRIMGMT-DES30XXP-MIB
Numeric OIDNameModule
1.3.6.1.4.1.171.11.63.7.2swL2MgmtMIBDES3028P-L2MGMT-MIB
1.3.6.1.4.1.171.11.63.7.2.1swL2DevMgmtDES3028P-L2MGMT-MIB
1.3.6.1.4.1.171.11.63.7.2.1.1swL2DevInfoDES3028P-L2MGMT-MIB
1.3.6.1.4.1.171.11.63.7.2.1.1.5swL2DevInfoFrontPanelLedStatusDES3028P-L2MGMT-MIB