basicHubSelfTest1

Module: DE1500-MIB

OID (symbolic): DE1500-MIB::basicHubSelfTest1

OID (numeric): 1.3.6.1.4.1.171.2.1.9

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

What is basicHubSelfTest1?

A read-write control to trigger the hub's first self-test routine by setting it to selfTest1(2); the default/idle value is noSelfTest1(1). Admins use this to run built-in hardware diagnostics remotely instead of visiting the device in person.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.171.2.1.9
snmpwalk -v2c -c public <target> DE1500-MIB::basicHubSelfTest1

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.171.2.1.9.1
snmpget -v2c -c public <target> DE1500-MIB::basicHubSelfTest1.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.171.2.1.9.1 i <value>

Start monitoring D-Link DE1500 series network device (legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the DE1500-MIB::basicHubSelfTest1 OID value, configure state conditions and alerts, and monitor any D-Link DE1500 series network device (legacy) from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.171d_linkDE1500-MIB
1.3.6.1.4.1.171.2hubmibDE1500-MIB
1.3.6.1.4.1.171.2.1basicGroupDE1500-MIB