Description: Determines the number of seconds between attempts to establish a connection for a Frame Relay to ATM circuit mapping.

Configuration Changed: operative

What is frpAtmConnectTimer?

This object sets, in seconds, how long the device waits between retry attempts when trying to establish a connection for a Frame Relay to ATM Network Interworking circuit mapping. An admin can shorten this interval to reconnect faster after a transient outage or lengthen it to reduce retry traffic on a persistently unreachable destination. For example, the default of 10 seconds means the device retries a failed FR-to-ATM connection attempt roughly every 10 seconds until it succeeds.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.495.2.1.6.3.51
snmpwalk -v2c -c public <target> CXFrameRelayATMIWF-MIB::frpAtmConnectTimer

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.495.2.1.6.3.51.1
snmpget -v2c -c public <target> CXFrameRelayATMIWF-MIB::frpAtmConnectTimer.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.495.2.1.6.3.51.1 i <value>

Start monitoring Legacy Crosscomm CX900/CX1000 router (Frame Relay/ATM interworking) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CXFrameRelayATMIWF-MIB::frpAtmConnectTimer OID value, configure state conditions and alerts, and monitor any Legacy Crosscomm CX900/CX1000 router (Frame Relay/ATM interworking) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.495memotecMEMOTEC-SMI
1.3.6.1.4.1.495.2memotecProductsMEMOTEC-SMI
1.3.6.1.4.1.495.2.1cxProductMEMOTEC-SMI
1.3.6.1.4.1.495.2.1.6cxApplicationCXProduct-SMI
1.3.6.1.4.1.495.2.1.6.3cxFrameRelayCXProduct-SMI
Numeric OIDNameModule
1.3.6.1.4.1.495.2.1.6.3.51frpAtmConnectTimerCXFrameRelayATMIWF-MIB