Type: MilliValue

Access: read-only

Description: The portCurrent represents the port current in milliamps. An integer like 50400 should be divided by 1000 for a value of 50.4 Amps.

What is portCurrent?

This value reports the current being drawn by the powered device on this port, in milliamps. An admin monitors it to catch a device pulling excessive current, which can signal a fault or an overloaded device. A reading of 600, for example, would mean the device is drawing 0.6 amps.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.40310.3.2.1.8
snmpwalk -v2c -c public <target> CUMULUS-POE-MIB::portCurrent

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.40310.3.2.1.8.1
snmpget -v2c -c public <target> CUMULUS-POE-MIB::portCurrent.1

Start monitoring Cumulus Networks switch (Power over Ethernet) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CUMULUS-POE-MIB::portCurrent OID value, configure state conditions and alerts, and monitor any Cumulus Networks switch (Power over Ethernet) from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.40310cumulusMibCUMULUS-SNMP-MIB
Numeric OIDNameModule
1.3.6.1.4.1.40310.3poeMIBObjectsCUMULUS-POE-MIB
1.3.6.1.4.1.40310.3.2poeObjectsTableCUMULUS-POE-MIB
1.3.6.1.4.1.40310.3.2.1poeObjectsEntryCUMULUS-POE-MIB
1.3.6.1.4.1.40310.3.2.1.8portCurrentCUMULUS-POE-MIB