CTRON-SFPS-VSTP-MIB :: vlanSpanningTreeSwitchForwardDelay

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CTRON-SFPS-VSTP-MIB › vlanSpanningTreeSwitchForwardDelay

vlanSpanningTreeSwitchForwardDelay

Module: CTRON-SFPS-VSTP-MIB

OID (symbolic): CTRON-SFPS-VSTP-MIB::vlanSpanningTreeSwitchForwardDelay

OID (numeric): 1.3.6.1.4.1.52.4.2.12.1.2.8.2.1.1.13

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Spanning tree forward delay value.

What is vlanSpanningTreeSwitchForwardDelay?

Sets the spanning tree Forward Delay, the time a port spends in each of the listening and learning states before moving to forwarding. An admin lowers this cautiously to speed up STP convergence, understanding it also raises the risk of a temporary forwarding loop if set too aggressively.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.52.4.2.12.1.2.8.2.1.1.13
snmpwalk -v2c -c public <target> CTRON-SFPS-VSTP-MIB::vlanSpanningTreeSwitchForwardDelay

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.52.4.2.12.1.2.8.2.1.1.13.1
snmpget -v2c -c public <target> CTRON-SFPS-VSTP-MIB::vlanSpanningTreeSwitchForwardDelay.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.52.4.2.12.1.2.8.2.1.1.13.1 i <value>

Start monitoring Legacy Cabletron switch (per-VLAN spanning tree) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CTRON-SFPS-VSTP-MIB::vlanSpanningTreeSwitchForwardDelay OID value, configure state conditions and alerts, and monitor any Legacy Cabletron switch (per-VLAN spanning tree) from a single console.

OID Breakdown

Upper-level ancestors (14 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.52cabletronCabletron-MIB
1.3.6.1.4.1.52.4mibsCT-PRIORITY-QUEUING
1.3.6.1.4.1.52.4.2ctronExpCT-PRIORITY-QUEUING
1.3.6.1.4.1.52.4.2.12ctVLANMibCT-PRIORITY-QUEUING
1.3.6.1.4.1.52.4.2.12.1ctVLANMgrCT-PRIORITY-QUEUING
1.3.6.1.4.1.52.4.2.12.1.2vlanInternalCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.12.1.2.8vlanSpanningCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.12.1.2.8.2vlanSpanningTreeSwitchCTRON-SFPS-INCLUDE-MIB
Numeric OIDNameModule
1.3.6.1.4.1.52.4.2.12.1.2.8.2.1vlanSpanningTreeSwitchTableCTRON-SFPS-VSTP-MIB
1.3.6.1.4.1.52.4.2.12.1.2.8.2.1.1vlanSpanningTreeSwitchEntryCTRON-SFPS-VSTP-MIB
1.3.6.1.4.1.52.4.2.12.1.2.8.2.1.1.13vlanSpanningTreeSwitchForwardDelayCTRON-SFPS-VSTP-MIB