All MIBs › CTRON-SFPS-VSTP-MIB › vlanSpanningTreeSwitchBridgePriority
vlanSpanningTreeSwitchBridgePriority
Module: CTRON-SFPS-VSTP-MIB
OID (symbolic): CTRON-SFPS-VSTP-MIB::vlanSpanningTreeSwitchBridgePriority
OID (numeric): 1.3.6.1.4.1.52.4.2.12.1.2.8.2.1.1.2
Node type: OBJECT-TYPE
Type: HexInteger
Access: read-write
Description: Spanning tree designated bridge priority.
What is vlanSpanningTreeSwitchBridgePriority?
Sets this switch's spanning tree bridge priority (in hex), the primary tiebreaker used when electing the root bridge. An admin lowers this value on the switch they want to force into becoming the network's root bridge.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.52.4.2.12.1.2.8.2.1.1.2 snmpwalk -v2c -c public <target> CTRON-SFPS-VSTP-MIB::vlanSpanningTreeSwitchBridgePriority
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.52.4.2.12.1.2.8.2.1.1.2.1 snmpget -v2c -c public <target> CTRON-SFPS-VSTP-MIB::vlanSpanningTreeSwitchBridgePriority.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.52.4.2.12.1.2.8.2.1.1.2.1 i <value>
Start monitoring Legacy Cabletron switch (per-VLAN spanning tree) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CTRON-SFPS-VSTP-MIB::vlanSpanningTreeSwitchBridgePriority OID value, configure state conditions and alerts, and monitor any Legacy Cabletron switch (per-VLAN spanning tree) from a single console.
OID Breakdown
Upper-level ancestors (14 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.52 | cabletron | Cabletron-MIB |
| 1.3.6.1.4.1.52.4 | mibs | CT-PRIORITY-QUEUING |
| 1.3.6.1.4.1.52.4.2 | ctronExp | CT-PRIORITY-QUEUING |
| 1.3.6.1.4.1.52.4.2.12 | ctVLANMib | CT-PRIORITY-QUEUING |
| 1.3.6.1.4.1.52.4.2.12.1 | ctVLANMgr | CT-PRIORITY-QUEUING |
| 1.3.6.1.4.1.52.4.2.12.1.2 | vlanInternal | CTRON-SFPS-INCLUDE-MIB |
| 1.3.6.1.4.1.52.4.2.12.1.2.8 | vlanSpanning | CTRON-SFPS-INCLUDE-MIB |
| 1.3.6.1.4.1.52.4.2.12.1.2.8.2 | vlanSpanningTreeSwitch | CTRON-SFPS-INCLUDE-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.52.4.2.12.1.2.8.2.1 | vlanSpanningTreeSwitchTable | CTRON-SFPS-VSTP-MIB |
| 1.3.6.1.4.1.52.4.2.12.1.2.8.2.1.1 | vlanSpanningTreeSwitchEntry | CTRON-SFPS-VSTP-MIB |
| 1.3.6.1.4.1.52.4.2.12.1.2.8.2.1.1.2 | vlanSpanningTreeSwitchBridgePriority | CTRON-SFPS-VSTP-MIB |