CTRON-SFPS-DIAGSTATS-MIB :: sfpsFloodCountersTotalSelfOrig

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CTRON-SFPS-DIAGSTATS-MIB › sfpsFloodCountersTotalSelfOrig

sfpsFloodCountersTotalSelfOrig

Module: CTRON-SFPS-DIAGSTATS-MIB

OID (symbolic): CTRON-SFPS-DIAGSTATS-MIB::sfpsFloodCountersTotalSelfOrig

OID (numeric): 1.3.6.1.4.1.52.4.2.4.2.2.6.2.2.4

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Total number of floods that the switch sees that were generated from itself.

What is sfpsFloodCountersTotalSelfOrig?

This integer counts floods that the switch detects as having been generated by itself rather than by an external device. Admins use it to catch a self-inflicted loop or firmware issue on the switch, as opposed to flooding introduced by connected end stations. For example, a nonzero value here despite no external flooding sources would prompt the admin to suspect the switch's own forwarding logic or a local loopback cable.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.52.4.2.4.2.2.6.2.2.4
snmpwalk -v2c -c public <target> CTRON-SFPS-DIAGSTATS-MIB::sfpsFloodCountersTotalSelfOrig

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.52.4.2.4.2.2.6.2.2.4.1
snmpget -v2c -c public <target> CTRON-SFPS-DIAGSTATS-MIB::sfpsFloodCountersTotalSelfOrig.1

Start monitoring Cabletron/Enterasys SmartSwitch switches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CTRON-SFPS-DIAGSTATS-MIB::sfpsFloodCountersTotalSelfOrig OID value, configure state conditions and alerts, and monitor any Cabletron/Enterasys SmartSwitch switches from a single console.

OID Breakdown

Upper-level ancestors (15 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.52cabletronCabletron-MIB
1.3.6.1.4.1.52.4mibsCT-PRIORITY-QUEUING
1.3.6.1.4.1.52.4.2ctronExpCT-PRIORITY-QUEUING
1.3.6.1.4.1.52.4.2.4ctronSwitchCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.4.2switchSFPSCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.4.2.2sfpsSwitchAgentCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.4.2.2.6sfpsAgentDiagnosticsCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.4.2.2.6.2sfpsDiagStatsCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.4.2.2.6.2.2sfpsFloodCountersResetCTRON-SFPS-INCLUDE-MIB
Numeric OIDNameModule
1.3.6.1.4.1.52.4.2.4.2.2.6.2.2.4sfpsFloodCountersTotalSelfOrigCTRON-SFPS-DIAGSTATS-MIB