All MIBs › CTRON-SFPS-DIAGSTATS-MIB › sfpsFloodCountersNonNetPort
sfpsFloodCountersNonNetPort
Module: CTRON-SFPS-DIAGSTATS-MIB
OID (symbolic): CTRON-SFPS-DIAGSTATS-MIB::sfpsFloodCountersNonNetPort
OID (numeric): 1.3.6.1.4.1.52.4.2.4.2.2.6.2.2.5
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: Total number of floods received on non-Network ports.
What is sfpsFloodCountersNonNetPort?
This integer counts floods received on ports not designated as network (inter-switch) ports. It helps an admin tell whether flood traffic is entering from an access/edge port rather than from the switch fabric uplinks, which changes where to look for the offending device. For example, a spike in this counter would direct the admin to check end-user access ports rather than trunk links between switches.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.52.4.2.4.2.2.6.2.2.5 snmpwalk -v2c -c public <target> CTRON-SFPS-DIAGSTATS-MIB::sfpsFloodCountersNonNetPort
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.52.4.2.4.2.2.6.2.2.5.1 snmpget -v2c -c public <target> CTRON-SFPS-DIAGSTATS-MIB::sfpsFloodCountersNonNetPort.1
Start monitoring Cabletron/Enterasys SmartSwitch switches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CTRON-SFPS-DIAGSTATS-MIB::sfpsFloodCountersNonNetPort OID value, configure state conditions and alerts, and monitor any Cabletron/Enterasys SmartSwitch switches from a single console.
OID Breakdown
Upper-level ancestors (15 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.52 | cabletron | Cabletron-MIB |
| 1.3.6.1.4.1.52.4 | mibs | CT-PRIORITY-QUEUING |
| 1.3.6.1.4.1.52.4.2 | ctronExp | CT-PRIORITY-QUEUING |
| 1.3.6.1.4.1.52.4.2.4 | ctronSwitch | CTRON-SFPS-INCLUDE-MIB |
| 1.3.6.1.4.1.52.4.2.4.2 | switchSFPS | CTRON-SFPS-INCLUDE-MIB |
| 1.3.6.1.4.1.52.4.2.4.2.2 | sfpsSwitchAgent | CTRON-SFPS-INCLUDE-MIB |
| 1.3.6.1.4.1.52.4.2.4.2.2.6 | sfpsAgentDiagnostics | CTRON-SFPS-INCLUDE-MIB |
| 1.3.6.1.4.1.52.4.2.4.2.2.6.2 | sfpsDiagStats | CTRON-SFPS-INCLUDE-MIB |
| 1.3.6.1.4.1.52.4.2.4.2.2.6.2.2 | sfpsFloodCountersReset | CTRON-SFPS-INCLUDE-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.52.4.2.4.2.2.6.2.2.5 | sfpsFloodCountersNonNetPort | CTRON-SFPS-DIAGSTATS-MIB |