All MIBs › CTRON-SFPS-COMMON-MIB › sfpsDiagLogSwitchIdleInterval
sfpsDiagLogSwitchIdleInterval
Module: CTRON-SFPS-COMMON-MIB
OID (symbolic): CTRON-SFPS-COMMON-MIB::sfpsDiagLogSwitchIdleInterval
OID (numeric): 1.3.6.1.4.1.52.4.2.4.2.2.6.1.1.1.16
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: Leaf to be used to set a debug variable. (in seconds)
What is sfpsDiagLogSwitchIdleInterval?
A debug timer, in seconds, defaulting to 30, governing how long the switch can sit idle before a diagnostic action triggers.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.52.4.2.4.2.2.6.1.1.1.16 snmpwalk -v2c -c public <target> CTRON-SFPS-COMMON-MIB::sfpsDiagLogSwitchIdleInterval
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.52.4.2.4.2.2.6.1.1.1.16.1 snmpget -v2c -c public <target> CTRON-SFPS-COMMON-MIB::sfpsDiagLogSwitchIdleInterval.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.52.4.2.4.2.2.6.1.1.1.16.1 i <value>
Start monitoring Cabletron SecureFast Packet Switch (SFPS), shared definitions with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CTRON-SFPS-COMMON-MIB::sfpsDiagLogSwitchIdleInterval OID value, configure state conditions and alerts, and monitor any Cabletron SecureFast Packet Switch (SFPS), shared definitions from a single console.
OID Breakdown
Upper-level ancestors (14 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.52 | cabletron | Cabletron-MIB |
| 1.3.6.1.4.1.52.4 | mibs | CT-PRIORITY-QUEUING |
| 1.3.6.1.4.1.52.4.2 | ctronExp | CT-PRIORITY-QUEUING |
| 1.3.6.1.4.1.52.4.2.4 | ctronSwitch | CTRON-SFPS-INCLUDE-MIB |
| 1.3.6.1.4.1.52.4.2.4.2 | switchSFPS | CTRON-SFPS-INCLUDE-MIB |
| 1.3.6.1.4.1.52.4.2.4.2.2 | sfpsSwitchAgent | CTRON-SFPS-INCLUDE-MIB |
| 1.3.6.1.4.1.52.4.2.4.2.2.6 | sfpsAgentDiagnostics | CTRON-SFPS-INCLUDE-MIB |
| 1.3.6.1.4.1.52.4.2.4.2.2.6.1 | sfpsDiagEventLog | CTRON-SFPS-INCLUDE-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.52.4.2.4.2.2.6.1.1 | sfpsDiagLogConfigTable | CTRON-SFPS-COMMON-MIB |
| 1.3.6.1.4.1.52.4.2.4.2.2.6.1.1.1 | sfpsDiagLogConfigEntry | CTRON-SFPS-COMMON-MIB |
| 1.3.6.1.4.1.52.4.2.4.2.2.6.1.1.1.16 | sfpsDiagLogSwitchIdleInterval | CTRON-SFPS-COMMON-MIB |