CTRON-SFPS-COMMON-MIB :: sfpsDiagLogRedirectorNumPackets

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CTRON-SFPS-COMMON-MIB › sfpsDiagLogRedirectorNumPackets

sfpsDiagLogRedirectorNumPackets

Module: CTRON-SFPS-COMMON-MIB

OID (symbolic): CTRON-SFPS-COMMON-MIB::sfpsDiagLogRedirectorNumPackets

OID (numeric): 1.3.6.1.4.1.52.4.2.4.2.2.6.1.1.1.14

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Leaf to be used to set how many packets the Redirector reads off at a time.

What is sfpsDiagLogRedirectorNumPackets?

How many packets the Redirector process pulls off the queue in one pass, defaulting to 64; raising it processes more packets per wakeup at the cost of burstier CPU use.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.52.4.2.4.2.2.6.1.1.1.14
snmpwalk -v2c -c public <target> CTRON-SFPS-COMMON-MIB::sfpsDiagLogRedirectorNumPackets

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.52.4.2.4.2.2.6.1.1.1.14.1
snmpget -v2c -c public <target> CTRON-SFPS-COMMON-MIB::sfpsDiagLogRedirectorNumPackets.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.52.4.2.4.2.2.6.1.1.1.14.1 i <value>

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> sfpsDiagLogRedirectorNumPackets.1

Start monitoring Cabletron SecureFast Packet Switch (SFPS), shared definitions with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CTRON-SFPS-COMMON-MIB::sfpsDiagLogRedirectorNumPackets OID value, configure state conditions and alerts, and monitor any Cabletron SecureFast Packet Switch (SFPS), shared definitions from a single console.

OID Breakdown

Upper-level ancestors (14 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.52cabletronCabletron-MIB
1.3.6.1.4.1.52.4mibsCT-PRIORITY-QUEUING
1.3.6.1.4.1.52.4.2ctronExpCT-PRIORITY-QUEUING
1.3.6.1.4.1.52.4.2.4ctronSwitchCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.4.2switchSFPSCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.4.2.2sfpsSwitchAgentCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.4.2.2.6sfpsAgentDiagnosticsCTRON-SFPS-INCLUDE-MIB
1.3.6.1.4.1.52.4.2.4.2.2.6.1sfpsDiagEventLogCTRON-SFPS-INCLUDE-MIB
Numeric OIDNameModule
1.3.6.1.4.1.52.4.2.4.2.2.6.1.1sfpsDiagLogConfigTableCTRON-SFPS-COMMON-MIB
1.3.6.1.4.1.52.4.2.4.2.2.6.1.1.1sfpsDiagLogConfigEntryCTRON-SFPS-COMMON-MIB
1.3.6.1.4.1.52.4.2.4.2.2.6.1.1.1.14sfpsDiagLogRedirectorNumPacketsCTRON-SFPS-COMMON-MIB