All MIBs › CTRON-POWER-SUPPLY-MIB › termPowerVoltage
termPowerVoltage
Module: CTRON-POWER-SUPPLY-MIB
OID (symbolic): CTRON-POWER-SUPPLY-MIB::termPowerVoltage
OID (numeric): 1.3.6.1.4.1.52.4.1.1.7.5.2
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: The voltage of the chassis's termination voltage rail. This rail carries power to INB terminator cards in the chassis. It has an allowalble range of 3.3 Volt + or - 5%.The value of this object is voltage * 100.
What is termPowerVoltage?
This is the measured voltage on the chassis's INB termination rail, which powers INB terminator cards and should stay within 3.3 volts +/-5%; the value reported is actual voltage times 100. An admin divides by 100 to get real volts when checking against that tight tolerance.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.52.4.1.1.7.5.2 snmpwalk -v2c -c public <target> CTRON-POWER-SUPPLY-MIB::termPowerVoltage
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.52.4.1.1.7.5.2.1 snmpget -v2c -c public <target> CTRON-POWER-SUPPLY-MIB::termPowerVoltage.1
Start monitoring Cabletron modular switch/router (power supply health) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CTRON-POWER-SUPPLY-MIB::termPowerVoltage OID value, configure state conditions and alerts, and monitor any Cabletron modular switch/router (power supply health) from a single console.
OID Breakdown
Upper-level ancestors (11 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.52 | cabletron | Cabletron-MIB |
| 1.3.6.1.4.1.52.4 | mibs | CTRON-AP3000-MIB |
| 1.3.6.1.4.1.52.4.1 | ctron | CTRON-MIB-NAMES |
| 1.3.6.1.4.1.52.4.1.1 | ctPhysical | CTRON-MIB-NAMES |
| 1.3.6.1.4.1.52.4.1.1.7 | ctps | CTRON-MIB-NAMES |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.52.4.1.1.7.5 | termPower | CTRON-POWER-SUPPLY-MIB |
| 1.3.6.1.4.1.52.4.1.1.7.5.2 | termPowerVoltage | CTRON-POWER-SUPPLY-MIB |